How About A Firebox Capacity and Dimensions Database?

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

velvetfoot

Minister of Fire
Dec 5, 2005
10,202
Sand Lake, NY
I think it would be very handy to have a database of firebox capacity and dimensions? Whatdya think? I have no idea how it could work. Start a thread and eventually put it into a spreadsheet? It would just be a matter of individual owners measuring their fireboxes and including, maybe, the published firebox capacity in ft3.
 
Yeah, I mentioned that idea a while back. We really need real numbers on the useable space rather than relying on mfr. numbers, which can be anywhere from 'pretty close' to 'way off.'
 
  • Like
Reactions: PapaDave
Yeah, I mentioned that idea a while back. We really need real numbers on the useable space rather than relying on mfr. numbers, which can be anywhere from 'pretty close' to 'way off.'

I imagine that simply setting the standard that everyone here from the forum would use for usable space when measuring would be tough due to the dozens of variations of stoves but if that standard was set I'd follow it to the letter because I too would totally be interested in such a sheet. Great Idea.
 
I can see noting the mfr's number for ft3 on the firebox (if they even publish it - I don't think they all do) if only because some fireboxes are not regular in shape. That whole irregular shape issue is a little tough.
 
I can see noting the mfr's number for ft3 on the firebox (if they even publish it - I don't think they all do) if only because some fireboxes are not regular in shape. That whole irregular shape issue is a little tough.
I think the mfrs. a lot of times measure the raw firebox size, without baffles, shields or whatever else is installed in there. We could get the square loading area, then note weather there is room at the top some where to fit in another small split or two.
 
I have no idea how the cat stoves look inside either. For mine, I would measure to the bottom of the secondary tubes.

I think it'd still be worthwhile to have the mfr's published value for the capacity.
 
I don't think measuring will be a problem. Pretty easy to figure the space usable for wood. Trick would be avoiding the nooks and crannies by only allowing a single measurement in each direction. In my experience with the hearthstone brand, the manufacturer is downright fraudulent in their advertised firebox volume.
 
. . .Trick would be avoiding the nooks and crannies by only allowing a single measurement in each direction. . .
+1
For uniformity, you'd have to stick with the biggest cubic rectangle that would fit in the stove. This might be the most unfair to the trapezoidal fireboxes, but there could be a column for notes about stuff like this. The system should only cater so much to mfrs who make a stove that takes a 16" split in the back and a 22" split in the front. Part of the "usability" of a firebox is how it can be loaded with wood that is processed to a uniform size, like all 16" splits. Mfrs of tapered fireboxes would kinda deserve what they get; the point of this spec is usability, and a tapered firebox is less usable than a rectangular firebox of the same volume, IMO.
 
I agree. I had one as I recall, the Quad 2700i. I can't see making use of that area except if you had a longer split. As you say, I can't see a way of loading the stove the max with, say, a 16" split that would fit in the back; There'd always be some space left over. I wouldn't penalize the stoves who could only load side to side though, right?

So you could have a measured usable space (ie, rectangle), and the mfrs published number for ft3, if it could be found.
 
The dimensions of the rectangle could be "average" vs. minimum so the tapered firebox would get some benefit. That would capture the volume.
 
. . .I wouldn't penalize the stoves who could only load side to side though, right?
Not sure what you mean. Front loading? Side loading? N/S vs. E/W log orientation? That would be useful info too.

So you could have a measured usable space (ie, rectangle), and the mfrs published number for ft3, if it could be found.
Sure, if you're doing a chart, might as well list multiple specs. :)

The dimensions of the rectangle could be "average" vs. minimum so the tapered firebox would get some benefit. That would capture the volume.
You could do a separate category for total volume, but I don't see how trapezoids are much different from nooks & crannies. Other than wedging scraps into the triangular spaces on the sides, the only way to make effective use of a trapezoid is to put, say, 16" splits in the back, then 18" splits in the middle, then 20" splits in the front. . .PITA, the opposite of usability. Only rectangles should be measured in the "usable space" category, IMO.
 
velvetfoot said: ↑. . .I wouldn't penalize the stoves who could only load side to side though, right?Not sure what you mean. Front loading? Side loading? N/S vs. E/W log orientation? That would be useful info too.

Right about the side to side. Yes, I meant front loading e/w, because the splits can't be loaded vertically. I guess, very short splits could be cut as well to fit it n/s, so I'd say no penalty for e/w.
 
That would certainly be the easiest way to go, yes you're right, it would be better information as well. Same deal with fireboxes that taper top to bottom as with bricks, the measurement should be the smallest dimension.
 
What about using some sort of agreed upon media to measure the usable space? Like say, how many 16" 4x4's (can be oriented in any direction) will fit? Then calculate the total volume occupied by the 4x4's (or 2x4's or whatever but 4x4's are pretty close to a normal sized split.) and use that as your "standard".

There used to be a standard here and was measured by how many cases of your favorite adult beverage would fit in the firebox..... :p;lol
 
Why not just use the measurement criteria from EPA Method 28 that is where the manufacturers got it in the first place.

"12.2.2 Firebox Volume. Determine the firebox volume in cubic feet. Firebox volume shall
include all areas accessible through the fuel loading door where firewood could reasonably be
placed up to the horizontal plane defined by the top of the loading door. A drawing of the firebox
showing front, side and plan views or an isometric view with interior dimensions shall be provided
by the manufacturer and verified by the laboratory. Calculations for firebox volume from
computer aided design (CAD) software programs are acceptable and shall be included in the test
report if used. If the firebox volume is calculated by the laboratory the firebox drawings and
calculations shall be included in the test report."

The BrotherBart Standard is:
 

Attachments

  • firebox.jpg
    firebox.jpg
    37.1 KB · Views: 376
"12.2.2 Firebox Volume. Determine the firebox volume in cubic feet. Firebox volume shall include all areas accessible through the fuel loading door where firewood could reasonably be placed up to the horizontal plane defined by the top of the loading door. A drawing of the firebox showing front, side and plan views or an isometric view with interior dimensions shall be provided by the manufacturer and verified by the laboratory. Calculations for firebox volume from computer aided design (CAD) software programs are acceptable and shall be included in the test report if used. If the firebox volume is calculated by the laboratory the firebox drawings and calculations shall be included in the test report."

While that is wonderfully scientific and all, we all know that sloping top baffles and protrusions into an otherwise rectangular firebox will have very little effect on the mathematically correct volume but a very real impact on how much actual wood you can get in there. I don't care how big the firebox is. (much ;lol) How much wood can I stuff in it?
 
Fill the thing with Styrofoam peanuts and then take them out and measure the volume. Please do it with a cold stove.

"all areas accessible through the fuel loading door where firewood could reasonably be
placed " says the same thing you are saying.
 
O
i'm even more jealous. and you have TWO of them? Amazing.

One is just hanging out in the basement not even connected. The deal was just too good to pass up.
 