high temp rtv

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

daffonce

Member
Jan 23, 2013
109
What do people use for high temp rtv. I realized that my installer didn't use it on the nipple to vent. I want to rectify that. Is 1500f fire blocker a suitable sealant for the exhaust?
 
usually Rutland brand , comes in caulking tube and small tube sizes , however you can also use high temp automotive rtv if the rutland isn't available near you .

No fireblocking is not suitable for this purpose .
 
nah just something like this-
Red-1.gif
 
Not sure if you're talking about the indoor or outdoor sections of pipe.....outdoor sections don't need to be sealed, except where the pipe goes through a wall or (obviously) a roof.

Any silicone with a 500::F or above rating will be fine.
 
  • Like
Reactions: Defiant
OK I was talking about the joint between the stove and first piece of vent pipe. I would like to seal it as the vent manufacturer and stove manufacturer recommends guess it was too much for the installer to do.
 
As noted above. Anything above 500* is fine. Seal that section well, as that's a positive pressure system and CO will leak out.

Did you smell or see smoke? Is that how you noticed it?

Please don't burn the stove until this is rectified!
 