Sorry to bother anyone! Light 4 flashing (Enviro M55) Can't reset****ALL FIXED****

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

bostonfan49

Minister of Fire
Nov 10, 2011
531
Essex Jct. Vermont
Stove shut off with T -stat Xmas eve, Started up At 5AM and heated up the house to 72, then at some point it went into shutdown mode and light 4 is flashing. When stove was completly cooled down, I unplugged the stove plugged it back in, fan ran for a bit and then went off. If I try to start to the stove, all that happens is light 4 flashes. [The Tech manual says Hopper is open or hopper switch has failed. Reset sensor and determine cause.
The 200F high limit temperature sensor has tripped] .......Any thing I can do? I don't know where any reset sensor is? Bumd out on XMass day. Thanks, Bill
 
The high limit should be on the back side of the stove. Check manual for a location maybe in the back of the manual there is a exploded diagram.
 
Checking manual, I can't...haven't learned yet how to pull stove out....if need be:(
 
I researched an old post M55 insert with same problem and folks talked about a rest switch under the front sliding top......??? Can't find anything.....Bill
 
**********PROBLEM SOLVED********** Thanks to all in an old post, same problem! I was able to reset the Hi/Lo temp switch.Stove running fine now! However reading the posts on this subject it would appear that some fan speed, pellet feed rate, air rate can bring this problem on...? Is this correct? Bill
 
There are two things you can do to take care of this problem:

1: Verify if your stove has the auger feed reducer plate installed, if not get it.

2: Verify the size of the convection blower on that stove, there is a new fan that has increased air flow (this is the rumored true fix to the over firing situation), hound your dealer until he caves, show no mercy if he won't do it as a warranty covered replacement.
 
Hey Smokey! All my parts manual says is "Auger Plate and Bushing", I take it, it's not the reducer plate. I guess I can Google it or check with Enviro.nDitto the new Covection blower motor. Happy Holidays! Bill
 
There are two things you can do to take care of this problem:

1: Verify if your stove has the auger feed reducer plate installed, if not get it.

2: Verify the size of the convection blower on that stove, there is a new fan that has increased air flow (this is the rumored true fix to the over firing situation), hound your dealer until he caves, show no mercy if he won’t do it as a warranty covered replacement.



So do the new units have these changes? I have mine 2 months now M55 FS when did they start the change?
 
Ditto on the model change, Mine was ordered in October...but it could have been sitting in a warehouse for months??? Bill
 
If the unit was shipped from the Enviro warehouse? There is a good chance its up to date with enhancements. But if your dealer had it in his own stock? Could have been over looked by your dealer.

If your unit has this convection blower(see picture)? It is the old version and should be updated with the new one to reduce the #4 flashing error. Also check your auger cover plate. It should have slots allowing adjustments to reduce feed with high BTU fuels.
 

Attachments

  • IMG_0433.jpg
    IMG_0433.jpg
    75.5 KB · Views: 1,119
Well he didn't have it in stock and he had the Cast M55 I ordered the M55FS which took a week to get plus he said It was the first one he ever ordered in the FS model. So maybe I have the updates.

As far as checking your auger cover plate. It should have slots allowing adjustments to reduce feed with high BTU fuels.
I'm not to fimilioar with the lingo maybe you could tell me just how and where to look.
 
The original cover looks like the picture. New one has slots to adjust it up or down to control pellet flow. Sorry I don't have a picture of the new one. Maybe a M55 owner can snap one for you?
 

Attachments

  • IMG_0007.jpg
    IMG_0007.jpg
    132.2 KB · Views: 1,094
Yes I believe I have the new style still full with pellets but can see and feel its very different then the picture shown. I wonder if that means I have the updated blower?
 
JIBLANE said:
Well he didn't have it in stock and he had the Cast M55 I ordered the M55FS which took a week to get plus he said It was the first one he ever ordered in the FS model. So maybe I have the updates.

As far as checking your auger cover plate. It should have slots allowing adjustments to reduce feed with high BTU fuels.
I'm not to fimilioar with the lingo maybe you could tell me just how and where to look.

Are you saying you have the steel freestanding unit? I don't know if they are updating the blowers in those. I'm not sure if this is the same all around the country, but up here my dealer orders from a regional distributor. So, if the regional distributor has lots of the old versions sitting around...guess what's going out the door first? So, it doesn't necessarily mean you are getting an updated stove just because your dealer doesn't have one in stock.
 
j-takeman said:
If the unit was shipped from the Enviro warehouse? There is a good chance its up to date with enhancements. But if your dealer had it in his own stock? Could have been over looked by your dealer.

If your unit has this convection blower(see picture)? It is the old version and should be updated with the new one to reduce the #4 flashing error. Also check your auger cover plate. It should have slots allowing adjustments to reduce feed with high BTU fuels.


Well, I will start with my Season's Greetings to all.

I was coming here to inquire about the #4 light flashing and realized someone else had the same issue before me.

So indeed, my M55 has the old style convection blower. When looking at the picture posted in this thread, I can clearly see that the motor drive shaft and the squirrel cage are misaligned probably due to the weight of the motor.

In my case, it causes a major alternating sideshift (like moving left to right every 2 seconds when heating on #3 setting). And at some point, it simply quits turning thus triggering the high temp limit switch.

When trying to heat at #4 and #5 settings, I get friction noises and not just the little thing: a real annoying and "about to fail" kind of noise.

So I took it apart, I unclipped the motor from the blower and rotated to motor 90deg CW (when looking from the control panel side). Then, I installed a little piece of wood between the motor and the steel frame of the stove, which brought alignment back to normal.... for a January 1st!!!

I will run to my dealer ASAP after holidays and will post my results.


Good to know about the auger plate too, I just found a new kind of pellets made from 100% hardwood and they are simply amazing (called PWI, btw). They now rank #1 in my favorite's list leaving LG's way behind!


On a final note, I would like to add this comment: to all forum members and adminsitrator, keep up the good work you do here, your forum is a source of very valuable information, well organized and well maintained!

Hoping to contribute a little more in the future as the girls grow older (they are 3 and 1!), they'll probably leave me more spare time...

Bye, Benski
 
My problem with convection blower on my M55 is solved. Sherwood Industries (Enviro) replaced my blower free of charge even though I was a good two months passed the warranty limit (original purchase in mid october 2009)

Thank you Sherwood!

Here is how it looks after it's installed:


In terms of noise, for me it ooes seem slightly louder, but it is a sound of air flowing through the tubes. The number of days I need to heat at 4 or 5 being so limited, it is no big deal.

I do recommend anyone having an issue with a flashing #4 light to not hesitate to install this new style blower.

By the way, instructions provided by Enviro were super clear and very easy to follow. Well done by Enviro!

Bye
 

Attachments

  • IMG_0353_2.jpg
    IMG_0353_2.jpg
    20.5 KB · Views: 858
Glad its all fixed for you benski. Also good to hear from you again and hope you have a good New Year.

Take care! ;-)
 