Single or double wall stove pipe

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

mj5001

Member
Oct 15, 2011
160
United States
I have no safety issues and no that the single wall obviously is hotter to the touch than double wall. I know also that double lasts much longer.

BUT, don't you lose some valuable heat with double wall? Would using single put more of your stove's heat into the room?
 
Unless you have a short chimney which could reduce draft or a long run over about 8' of stove pipe I'd go with single wall.
 
I would say it depends on the stove. On a good EPA stove your flue temps aren't going to be very hot and it's heat that you probably want being used for creating draft.
 
Double wall lasts no longer than single wall.

The purpose of the outer wall is simply a heat shield, whether you need to keep heat in to keep the flue warm, or to reduce clearances to combustibles.

But once the flue burns or rots through, it's done.
 
  • Like
Reactions: oldspark
I went with double wall because of clearance issues and a short chimney, I would say if you don't need it don't use it. It's also a lot more expensive than single wall.
 
Dakotas Dad said:
Double wall lasts no longer than single wall.

The purpose of the outer wall is simply a heat shield, whether you need to keep heat in to keep the flue warm, or to reduce clearances to combustibles.

But once the flue burns or rots through, it's done.
Not true, double wall has a Stainless Steel inner wall, in normal conditions, it will never wear out.
 
webby3650 said:
Dakotas Dad said:
Double wall lasts no longer than single wall.

The purpose of the outer wall is simply a heat shield, whether you need to keep heat in to keep the flue warm, or to reduce clearances to combustibles.

But once the flue burns or rots through, it's done.
Not true, double wall has a Stainless Steel inner wall, in normal conditions, it will never wear out.
Well I have 30 year old single wall that looks like new so guessing it will go another 30 at least, l will be in the grave before it is.
 
  • Like
Reactions: gyrfalcon
With an EPA stove, the heat that comes off the pipe isn't a substantial amount. Unless the stove is wide open, there's not much heat coming off of it, there is enough to cool the flue though. When I clean a flue that has double wall, it's much cleaner, often very little build up. If it's not needed for clearance reasons, I wouldn't bother with it due to the expense. If you go with single wall, get the 22ga factory crimped pipe, it will last many,many years.
 
oldspark said:
webby3650 said:
Dakotas Dad said:
Double wall lasts no longer than single wall.

The purpose of the outer wall is simply a heat shield, whether you need to keep heat in to keep the flue warm, or to reduce clearances to combustibles.

But once the flue burns or rots through, it's done.
Not true, double wall has a Stainless Steel inner wall, in normal conditions, it will never wear out.
Well I have 30 year old single wall that looks like new so guessing it will go another 30 at least, l will be in the grave before it is.
So i guess you have an all vertical run? Or 22 gauge pipe?
 
My stove pipe is not all that cool during the gas off phase, I like to have it around 300 surface temp for the most part, 600 or so on start up and reload.
 
webby3650 said:
oldspark said:
webby3650 said:
Dakotas Dad said:
Double wall lasts no longer than single wall.

The purpose of the outer wall is simply a heat shield, whether you need to keep heat in to keep the flue warm, or to reduce clearances to combustibles.

But once the flue burns or rots through, it's done.
Not true, double wall has a Stainless Steel inner wall, in normal conditions, it will never wear out.
Well I have 30 year old single wall that looks like new so guessing it will go another 30 at least, l will be in the grave before it is.
So i guess you have an all vertical run? Or 22 gauge pipe?
24 gauge with 2 90's
 
oldspark said:
webby3650 said:
oldspark said:
webby3650 said:
Dakotas Dad said:
Double wall lasts no longer than single wall.

The purpose of the outer wall is simply a heat shield, whether you need to keep heat in to keep the flue warm, or to reduce clearances to combustibles.

But once the flue burns or rots through, it's done.
Not true, double wall has a Stainless Steel inner wall, in normal conditions, it will never wear out.
Well I have 30 year old single wall that looks like new so guessing it will go another 30 at least, l will be in the grave before it is.
So i guess you have an all vertical run? Or 22 gauge pipe?
24 gauge with 2 90's
Extraordanary!
 
Might have something to do with dry wood and not smoldering the fire.
 
I went with Simson DVL double wall. I had plenty of clearance and could have used single wall.
My chimney is a little on the short side and it has an offset so I figured the double wall would be a good idea. Drafts fine no problems.

I do think DW should last longer, the inside is stainless steel, the single wall on my basement stove is only 4-5 years old and has some corrosion on the inside. I vote for DW.
 

Attachments

  • Picture 143.jpg
    Picture 143.jpg
    48.1 KB · Views: 4,533
MJ5 said:
I have no safety issues and no that the single wall obviously is hotter to the touch than double wall. I know also that double lasts much longer.

BUT, don't you lose some valuable heat with double wall? Would using single put more of your stove's heat into the room?

I use my woodstove to heat the house . . . and the stove pipe to simply let the waste gas out of the house.

I mean sure . . . there may be some heat gain from single wall vs. double wall . . . but in my own case my house is plenty warm with the double wall. I think if most folks size their stove right and run their stove right the heat gain from single wall vs. double wall will not matter a whole lot.
 
WES999 said:
I went with Simson DVL double wall. I had plenty of clearance and could have used single wall.
My chimney is a little on the short side and it has an offset so I figured the double wall would be a good idea. Drafts fine no problems.

I do think DW should last longer, the inside is stainless steel, the single wall on my basement stove is only 4-5 years old and has some corrosion on the inside. I vote for DW.
Just curious, why did you elbow at the stove? It's more common and would draft a bit better if the elbows are at the ceiling box. I'm glad it's drawing good for you.
 
Just curious, why did you elbow at the stove? It’s more common and would draft a bit better if the elbows are at the ceiling box. I’m glad it’s drawing good for you.


I figured it would be a little easier to clean. The brush can goes straight down until the very end, then it would make the jog and come out in the stove.
 
I elected to go all the way with double wall, figuring that it would keep the temps higher and less creosote.
 
Well I only have about 53 inches of stove pipe so no way in hell am I going to pay for double wall, your set up will dictate if you need it or not.
 
Glad to read this debate... I'm in the process of deciding for myself here as I consider my upgrade from FV to PH. I have single wall now but I know I may have marginal draft at times. I added 3' to the top of my chimney that solved some downdrafts at startup and possible backpuffing the first year with the FV so I know I'm on the edge for the FV. I haven't discussed with WS yet - probably should of course. But I wonder just how much difference (if any) it could make to swap out the approx 4.5' of single wall pipe in the house. On one hand it seems it is too little distance to matter, but this is the hottest part of the flue gas exit and when I clean the pipe it is the only part of the chimney system that really has any real buildup so I know that there is some cooling going on here. IF I am going to do this, this is the time to do it - once the PH is in place I sure don't want to re-do anything!
 
Slow1 IMHO 4.5 feet wont amount to a hill of beans for draft, that short of single wall pipe should not be that cool at all unless you happen to be one of those with a setup that has a cooler flue, if you monitor your flue temps that one thing should tell you if you need double wall but for 4 feet I think it is a waste of money.
 
oldspark said:
Slow1 IMHO 4.5 feet wont amount to a hill of beans for draft, that short of single wall pipe should not be that cool at all unless you happen to be one of those with a setup that has a cooler flue, if you monitor your flue temps that one thing should tell you if you need double wall but for 4 feet I think it is a waste of money.

With the FW, I have a thermometer about 2" above the stove. I engage the cat at about 300* and it generally cruises at around 250* at high end, then falls from there - bulk of the time spent around 220*.

External is all ClassA exposed to the elements. I get icicles hanging off my cap when it is colder that fall of when I reload.

So - am I one of those with a cooler flue?
 
I think cat stoves run with a cooler flue correct, the question would be how much are you going to gain by only 4.5 feet of DW pipe, not much I bet, short runs of single wall pipe have little effect on the cooling of the flue.
 
I will add if you are willing to spend the money and you think you need it by all means put it in, just dont listen to the hype of the single wall pipe does not last long, I have seen sites that say you hae to change it out every few years and that is just some one who knows nothing about wood burning. If you have to change out your pipe that often you are burning with out a brain, I dont think even the cheapest pipe wont burn out that quick.
 