Econoburn Overheat Relay - Tieing 120v to existing 24v system

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

SIERRADMAX

Feeling the Heat
Jan 13, 2011
300
RI
I understand the principle behind the 120v overtemp protection relay. However, I need to find out how to tie it into my existing system without adding zone valves/circulators.

My current heating system uses 24v zone valves. Thermostat calls for heat, opens the zone valve and powers the circulator through an 8148 Aquastat Controller.

Without adding a dedicated 120v zone valve for the overtemp relay, I would like to install a 24v step down transformer and tie the feed into an existing zone valve. In retrospect, making the wood boiler act as a thermostat. However, won't the feed from the existing thermostat back-feed through the newly added 120v/24v overtemp relay when the thermostat calls for heat, and vice-versa? Econoburn mentions that the overtemp relay is a rare occurance. And the chances are that both call at the same time is even more so.

I've gotten several mentions of a rib relay but I'm unfamiliar with these and specifically which one would suite my application. Any suggestions?
 
I'm not sure what rib relay is? I used "Ice cube" relay. Run the 120 volt over temp signal to the coil of the relay. Then the 24v to thermostat can also be run to a N.O. contact on the relay. Come out of the N.O.Contact and to the zone valve that the thermostat controls. Now the thermostat or the overtemp from wood boiler will turn valve on.
 