enviro fire EF 2 fan controller switch still has no control

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

Evi Morrison

New Member
Dec 21, 2012
27
hopefully some one on here can help me out because i am lost. i did exactly what every manuel has said to test the switch and and they all point to the fan controller switch being bad. replaced the switch and still no control. would like some help on this problem I'm right now lost on what else could be the problem. any insight to this would be great thanks.
 
Hello

I repaired an EF-3 blower fan knob a couple of weeks ago . I believe it is similar to the EF-2. In this case the potentiometer was correctly changing resistance to bias the Triac to reduce the fan voltage to lower the room fan speed. However the Triac was bad and the fan would only run on high. Therefore I replace the module with a new Fan speed knob and resolved the problem. I also put the stove on a surge protector. Any power surges after a storm can ruin the Triacs on most pellet stove control boards.
Here is the part
http://www.stove-parts-unlimited.com/Enviro_Fan_Controller_with_Knob_115V_p/ef-045.htm
 
The link you sent me sends me to a fan controller. I don't think that's the part you wanted me to go to. I already replaced that. Not sure what the triac is. It looks like the wires go to a blue box in the back of the stove then to the blower. Is the blue box what your talking about ?
 
The link you sent me sends me to a fan controller. I don't think that's the part you wanted me to go to. I already replaced that. Not sure what the triac is. It looks like the wires go to a blue box in the back of the stove then to the blower. Is the blue box what your talking about ?

The Triac I am referring to is in that Fan Controller box.
I posted a picture of the triac. It is in the 3rd pic here of my thread.
https://www.hearth.com/talk/threads/enviro-ef-3-room-blower-only-runs-on-high.103408/#post-1337256

The blue box you are referring to is the Auger Timing module that only controls the auger timing for the different heat settings.

If you look at the wiring diagram on page 31 of the owner's manual you can see.
http://www.enviro.com/images/manuals-brochures/owners-manuals/C-11219 Instruction EF2 Domestic Owner's Manual.pdf
 