FOXMAN

New Member
Nov 5, 2013
7
Wisconsin
Hi, New to the site and having a problem with my St Croix Hastings stove. When I fire up the stove it seemed like the combustion fan was running slow and the stove wouldn't start up. I unhooked the blower and jumped 120 vac. straight to the blower and fired it up and it lit and runs fine. I heard that the control board going out on these is a common problem. Anyone know a way to test the board? I hate to buy one if I don't need one...
 
You can push a sewing pin into the black and white wires going to the comb fan motor and check voltage w/ a multi meter. When you first start the stove you should see full line voltage for about 5-10 seconds then it should drop to 105v maybe. Are you sure the fan is running slow or does it just seem like there is not enough air to sustain a fire? Is there a chance that there is a clog in the stove?
 
Thanks for replying... I'm sure the motor is running slow. Some times during start up it actually almost stopped completely. I will check the voltage when I get done with work. If the voltage is low do you think it's the board?
 
When is the last time you pulled the fan out and cleaned under it, cleaned the blades, lubed it and replaced the gasket?

I would think it was the fan before the control board. There are safeties and it sounds like the stove is doing what it should do if the fan is bad.
 
Last edited:
When is the last time you pulled the fan out and cleaned under it, cleaned the blades, lubed it and replaced the gasket?

I would think it was the fan before the control board. There are safetys and it sounds like the stove is doing what it should do if the fan is bad.
X2 this would be the place I would start. Also on my St. Croix Lancaster, basically the same guts, my fans didn't really get going great, so I cleaned all the connections to the fans and what a difference. I have also pulled the combustion blower and cleaned in there along with the blades on the fan. I would try all these type of things before getting a control board.
 
I have pulled and cleaned the combustion fan this time (and several other times before because of bad pellets) The fan runs great when wired direct to 120 vac. I will check the voltage the board is sending out when I get a chance. Again, Thanks for the replys. This site is awesome!
 
On my Afton Bay, a lot of the workings go to a common neutral buss mounted on the back of the stove. You may have a similar setup - if so, make sure all the connections there are good. It's not too likely your board is bad, more like a bad connection.
 
On my Afton Bay, a lot of the workings go to a common neutral buss mounted on the back of the stove. You may have a similar setup - if so, make sure all the connections there are good. It's not too likely your board is bad, more like a bad connection.
Thanks for the advice. I will check that also...
 
checking voltage going to the motor will tell you which way to to go next. I have seen the st croix boards do some weird things.
 