Smoke problem in basement

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

tom

New Member
Nov 10, 2013
3
NJ
I'm having problems with smokey smell in our basement near the fireplace when we have a fire in the upstairs fireplace. We have a double sided fireplace in our living room and a single sided directly below it in the basement. The chimney has three flues; one for up, one for down and one for the boiler, all three side by side. We don't use the boiler chimney anymore since we have power vent. Not sure if it is a problem of positive/negative pressures pulling smoke in from the top of the chimeys all the way to the basement or if it is a leak in the mortar joints or something like that. We keep the fireplace doors open when we have a fire upstairs. No chimney caps on top, so maybe I should start there? Not sure who I would get to look at either. Seems technical and maybe not for your average chimney guy. Thanks.

Also, looking to put a coal stove in downstairs to assist with heating bills. Should a coal stove typically smell? Wife is concerned.
 
This could be a combination of low basement pressure and the identical height flues. Extending the upstairs flue will help. Take a look at the extendaflue boost cap.
 
I agree with begreen on this. Same height can really cause problems.
 
I would cap the flue. I think you are pulling air in from the flue not being used. Also make sure you have a source of make up air
 
crack a window and see if it helps... probably negative pressure in the house pulling air down that other chimney...
 
crack a window and see if it helps... probably negative pressure in the house pulling air down that other chimney...
yep. That should do it. I have replaced a few spill switches on my boiler due negative pressure
 
A upstairs window open can actually cause it by pulling on the intake air.
 
Status