Whitfield shutting down after 30 mins

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.

Ranger72

Minister of Fire
Oct 11, 2014
540
Long Island, NY
Hey guys, Stove started turning off after 30 mins exactly. I jumped the low temp switch for temporary use and ordered a new one. Installed it today and it is doing the same thing still! So I guess the low temp switch is good, but then what can it be??? Control board? Thanks
 
Does your stove think its on thermostat and heat isn't needed?
 
Unsure, I have never used a thermostat though
 
Yes, with the switch jumped out will work, but not with using either the new or old switch
 
Or the high limit is closing too early. but then it wouldn't work jumped. New switch could be bad.
 
Wouldn't the high limit switch be causing the stove to shut down whether or not the low limit was jumped?
 
You posted before I edited my post. All the low limit switch does is connect the two wires, just like the jumper. Should be no control board involved here.
 
That is what I thought originally, but then the stove knows to bypass the switch when the stove is first turned on and the exhaust temps are below 140 degrees. I am at a loss.
 
As I recall, Stovensen is the Whit guru, with several manuals as well. Perhaps private message him?
 
  • Like
Reactions: Ranger72
Thank you!
 
I have been remodeling a room in my home and brain was kind of side tracked. Just thought about it and the replacement switch must be stuck open. Only thing that makes sense. I'll confirm this with my meter on the AM while stove is cool.
 
You can heat the switch with a lighter while monitoring the terminals with a meter - with the switch out of the stove.
 
  • Like
Reactions: Ranger72
Yep, that is the plan for the morning. Thanks
 
It seemed pretty clean, I also just cleaned the motors a few weeks ago. I did put a tiny bead of RTV on the mounting side of the new switch. I don't think that would interfere with anything though. I have to run to Home Dopey and pick up a new multimeter as apparently my old one sh#it the bucket.
 
It seemed pretty clean, I also just cleaned the motors a few weeks ago. I did put a tiny bead of RTV on the mounting side of the new switch. I don't think that would interfere with anything though. I have to run to Home Dopey and pick up a new multimeter as apparently my old one sh#it the bucket.

There should be nothing that gets between that switch and what it mounts against or behind where it mounts if it is a ceramic air stream the switches sensor can get covered in ash and fail to operate in time, if it mounts against the metal blower case the area behind the case where the switch mounts can become insulated (read not conduct the heat very well) by ash as well. Then we have the all seeing photo cell POF systems that usually get the fines, ash, lens scaring that leads to them not seeing the fire through the magical; mystery port such that even a good photo eye can't do its job.

Short of tc systems I think I just covered most older stoves. Dirt is the first thing I think of, those switches last through many thousands of cycles, as long as they don't use Bakelite (read plastic) switches in a high temperature application (which some do).

That would also explain why replacing the "bad" switch with a "good" one still doesn't work. Only since you used some RTV (a relatively good insulator, [read dirt ash etc...]) .......
 
  • Like
Reactions: heat seeker
Thanks for info! Just bench tested both switches, both work. Going to check for instructions, dust, dirt etc in the mount area
 
Well 20 mins left and we shall see. I cleaned off the Rtv and reinstalled. I cleaned the old one off for good measure and saved it. I heard the switch 'click' when it got hot.
 
All good so far. Thanks guys!
 
I’m having simular issue with my Whitfield stove. I’ve tried jumpering the low limit switch and cleaned it. It worked for about 30min building up a supply of pellets in burn pan then stops feeding. Once it mostly burnt up the auger starts dumping pellets again.

Any help would be appreciated
 
I’m having simular issue with my Whitfield stove. I’ve tried jumpering the low limit switch and cleaned it. It worked for about 30min building up a supply of pellets in burn pan then stops feeding. Once it mostly burnt up the auger starts dumping pellets again.

Any help would be appreciated
I recommend you start a new thread,and put in make,model,year of stove.