Powervent oil burner and connect Englander add-on to masonry chimney?

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

Badfish740

Minister of Fire
Oct 3, 2007
1,539
I installed my Englander furnace about six years ago and put up a brand new Class A stainless chimney. I've never really been crazy about how it looks, or the fact that I have two chimneys on the side of the house. It just looks awkward. The furnace sits right next to the oil burner. We are looking at a potential major renovation of our house this summer, and part of that renovation will be moving all of the ductwork to the attic via a chase through the first floor. The reason for this is because the previous owner butchered the original system in order to accommodate a finished basement. It is horribly inefficient in terms of air flow. In any event, the entire HVAC system is going to torn apart anyway, so if there's going to be a time to make a change, it's then. Here's the plan:

Move the wood furnace to the opposite side of the oil burner from where it is now, which will locate it right under the (clay lined) masonry flue. Routing the hot air delivery plenum will be just as easy as before. The oil burner could then be powervented through where the Class A chimney exits now. Then I'll have one chimney that I can then really insulate well as we'll be applying foam board to the entire exterior and residing during the renovation. That said, I have no experience with powervents. I'm pretty sure one of my neighbors must have one because their house has no masonry chimney at all nor any tell tale galvanized pipes sticking out of the roof. With regard to the existing Class A I'll hold onto it as I'll either use it for a small stove in an outbuilding, or possibly a stove for the living room down the road.
 
How far are the two chimneys apart? Maybe you could enclose them in a chase? Mine is like 6' wide. There are 3 flues in it: the left one has the oil burner, the center one has the insert on the first floor, and the right one has the pellet boiler. Maybe you could do something similar and put in a fireplace/insert.
A friend of mine has an oil fired power vent and she likes it. I was thinking of going that route at one time, but I found a chimney guy that could add the flue in the chase.
 
listen to one while its running before deciding.
 
I had one in the crawl space at our island cottage. Ran it once and took it out. Way to loud. Yes the windows were closed.
Dreaming of a pellet boiler for replacement.
 