We found a 45, and it says ameri-vent 3EAL type B-gas vent. It's 3" and fits with our pellet piping. It's only missing the insulation roping that's in the other piping, but we can get that at curtis lumber.

Will it work?

Thanks!!
 
brandytab said:
We found a 45, and it says ameri-vent 3EAL type B-gas vent.
Thanks!!


It may fit but it's not the right vent to use. Pellet stoves require PL vent.
 
Absolutely not what you have found is B-vent meant for venting gas appliances. The inner liner of that is likely going ot be aluminium and will turn to swiss cheese if used in a wood/pellet installation.
 
I know that the B gas vent won't hold up long term but I also know that it's cheap and would allow her to do the rest of the install now so my question is could the elbow be used temporarily until a pellet elbow can be shipped to her? Is this just to dangerous to do since the elbow would be inside the house?
 
pegdot said:
I know that the B gas vent won't
hold up long term but I also know that it's cheap and would allow her to do the
rest of the install now so my question is could the elbow be used temporarily
until a pellet elbow can be shipped to her?


It wouldn't pass inspection with the gas vent. And even if someone didn't care
about that aspect, once you've sealed the joints with the hi temp rtv and put the
three screws in each joint, it's a pita to separate this stuff.
For those reasons and the fact that I believe in doing it right the first time,
I wouldn't use it.
 
THIS IS FOR YOUR SAFETY
DO NOT MIX AND MATCH BRANDS The fitting are not the same

DO NOT USE B vent for a Pellet stove
DO YOU WANT YOU FAMILY TO WAKE UP TOMORROW?
 