deep wood

New Member
Jul 20, 2008
30
AK
I purchased the Quadra Fire Castile and I'm currently planning the install. Is the Top Vent Adapter kit required for an "up and out" installation or may a person substitute a double walled "T" (the bottom of the T capped and used for cleaning access) plus a vertical (approximately 60") run, with double walled pipe, then out. My dealer does not have the Top Vent Adapter Kit in stock. Thanks in advance for replies and advice!
 
I didn't even know there was a top-vent adapter kit for the Castile.

I did exactly what you're asking about with my Castile, directly out of the stove with a 3" "T" with a cleanout on the bottom, then mine goes straight up 14' throught the ceiling and roof. All Simpson Duravent Pro.

Steve
 

Attachments

  • Stove53s.jpg
    Stove53s.jpg
    144.4 KB · Views: 1,110
According to the owners manual a top vent kit is shown for an up and out installation. Here is the pdf link to the manual Linky poo
 
Shortstuff said:
I did exactly what you're asking about with my Castile, directly out of the stove with a 3" "T" with a cleanout on the bottom, then mine goes straight up 14' throught the ceiling and roof. All Simpson Duravent Pro.

Steve

Holy cow.....that looks like a pain to clean. I had mine go straight out the wall...with the tee outside the wall and then went approx. 8' up. A snap to clean :) No mess .
 
so how do you guys like the Castilles?

think you can heat a well-insulated 1600 sq ft house with one?
 
Thanks for the replies.....my "up" must be inside since my floor is 40" below grade. I agree cleaning may be problematic but it appears any corner installation will be a tight fit and difficult to access the clean-out. Does anyone disconnect their stove from the exhaust vent and move it away from the wall/corner to clean the exhaust vent?
I'm thinking about the difficultly of breaking the silicone seal on the exhaust pipe.
 
The rear to top kit has a side cleanout door making it easier to clean. It also mounts to the stove which will support the weight of a full vertical install. I have never seen anywhere that it is required but I think it makes a cleaner looking install.
 
Good point!, I didn't consider the weight and support of the exhaust pipe. I will ask my dealer to order the kit.....

Thanks for the help!
 
I have a Castile. I went out the back of the stove to a T, went up 6 feet, then out the wall and capped it. Been like that for 3 years without a problem. You don't need to the outside air kit or the top vent kit unless you want it. It's not necessary.
 
I called the dealer today, she claims she is having trouble finding a top vent kit as her suppliers are sold out, it's nice to know I have other options....thanks!
 
Here is my stove without the top vent. Hard to see as it wasn't a close up.
 

Attachments

  • Stove.jpg
    Stove.jpg
    18.2 KB · Views: 887
deep wood said:
Fire it Up:

What is your technique for cleaning the exhaust vent? Is it relatively easy with your system?

Twist the cap, shop vac, then put the shop vac house in the base of the pipe and bang it slightly. Everything that falls goes right into the vac. On the outside I just shove the shop vac into the horizontal run and clean it.

I'm a neat freak and don't have any issues with ash going everywhere. Even if it does, the shop vac takes it all up.
 
They must be blind, it is right in the price book.
 