Hearth too short by 2 inches!

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

thebingo

New Member
Aug 21, 2008
7
auburn, ma
Just purchased the Napoleon npi40 for the house. Hearth is 16 inches..Npi40 requires six inches from front of door. so i need two more lousy inches to pass inspection. What to do? Hearth is flush with hardwood floor too. Can I get a extension or build a two inch extension. Napoleon specs r value= .40 for hearth
 
With my stove it was 6" from the front of the stove "Measured from the glass", so you might want to double check that measurement starting from the surface of the door glass out.

Steve
 
It may not be pretty, but you could get one of the approved stove mats.
Friend of mine has his P38 sitting on one. I would think you can put it
right in front of the stove to make up for the 6 inches. I think he bought
it at Lowes or Home Depot.
 
thebingo said:
Just purchased the Napoleon npi40 for the house. Hearth is 16 inches..Npi40 requires six inches from front of door. so i need two more lousy inches to pass inspection. What to do? Hearth is flush with hardwood floor too. Can I get a extension or build a two inch extension. Napoleon specs r value= .40 for hearth

That what my wife says (need two more inches) lol lol lol
 
chuckpp said:
thebingo said:
Just purchased the Napoleon npi40 for the house. Hearth is 16 inches..Npi40 requires six inches from front of door. so i need two more lousy inches to pass inspection. What to do? Hearth is flush with hardwood floor too. Can I get a extension or build a two inch extension. Napoleon specs r value= .40 for hearth

That what my wife says (need two more inches) lol lol lol
send her my way :lol:
 
NPS40:
The heater must be installed on a non-combustible fl oor protector extending the full depth of the heater and extending a
minimum 6" in front and on either side (minimum .018" thick - 26 gauge).
The fl oor protector must extend under and 2" beyond each side and rear of a "Tee" (if used).
NPI40:
In the case of the NPI40, the fl oor protector must have a R-value of 0.4 hr ft²°F with a minimum of 6 inches from the front.

im so confused.
 