Englander 25-PDV(E) E-3 Errors

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

Maj_Jedi

New Member
Nov 23, 2008
10
Central ME
got a strange error over the last several days. after 5-6 hours of use my englander gets an E-3 (overheat error) even on a setting of 1 fuel 9 blower (1-9) This started in the last week. It didn't happen when we were running it at 50 degrees, but now that it is below 30 at night it seems to do it more often.

there is also a lot of soot on the glass (we have to clean it every other day) the same soot is all over the inside too. is this normal? the soot is fine, white and flakes off.

how long should I be able to run the stove at 1-9 before I get E-3?

is it normal for the pellets to pile up during ignition? the pile reaches almost the top of the burn pot
 
E-3 is a combustion blower failure error....Better check the flue...blower for built up ash and such.They also say check the wires...then call tech support
 
Smudge88 said:
E-3 is a combustion blower failure error....Better check the flue...blower for built up ash and such.They also say check the wires...then call tech support

are there directions on how to do that?
 
Did you get a DVD with the stove? There are instructions on how to clean each part of the Englander in the DVD.
 
Maj_Jedi said:
Smudge88 said:
E-3 is a combustion blower failure error....Better check the flue...blower for built up ash and such.They also say check the wires...then call tech support

are there directions on how to do that?

If you have the DVD that came with the stove, I believe it explains blower removal in there. It's actually pretty easy even if you are not mechanically inclined. One side note, you will need a new gasket if you pull the motor unless you use high temp silicone upon assembly.
 
hopefully englander tech support gave me the right solution the "AIR ON TEMP" was set to 9, the tech said that was way too high and had me turn it down to 1
 
Air on temp should definitely be at 1. Hopefully this fixes you up.
 
hopefully englander tech support gave me the right solution the “AIR ON TEMP” was set to 9, the tech said that was way too high and had me turn it down to 1
Geeze ya....I wonder why that setting is even that easily adjustble...Wish you said that last night when you posted...Good Luck!
 
Smudge88 said:
hopefully englander tech support gave me the right solution the “AIR ON TEMP” was set to 9, the tech said that was way too high and had me turn it down to 1
Geeze ya....I wonder why that setting is even that easily adjustble...Wish you said that last night when you posted...Good Luck!

I didn't even KNOW how to get to the setting, the tech had to tell me like four times to how to get to it. what does that setting do?
 
This setting adjusts the room fan on temp....which explains your over temp shut down...the are 3 buttons on the bottom of the control board...low fuel feed..low fuel air...and the 3rd one that you shouldn't change...it can happen....as you found out.
 
Status
Not open for further replies.