electronic problem with quadra fire stove

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

sryan

New Member
Nov 22, 2009
3
pa
i just bought a used quadra fire pellet stove. hooked it up and it ran great for 20 min than the auger shut off as soon as the distribution fan kicked in. tried resetting it and the same thing happened
 
What did you reset? Was it a snap disc? Possible bad snap disc. Try jumping it and if problem doesn't persist, bad snap disc.
 
its a 1100 quadra fire pellet insert. there is a reset on the side with an amber light. i tried wiring the thermostat direct to see if that was the problem but same results. there is a board box above the reset that clicks then the auger shuts off and the stove goes out,the green led light on the box stays lit
 
I'll bet the stove is plugged with ash...
 
I think the amber light means a thermocouple error.
 
Sounds like the thermo-couple to me. It's not sensing the stove is lit so it is shutting down the feed.
 
If you see the green light, then you reached 200 degrees but if you don't see the red light (not the 'call for heat' red light) then you never reached 600 degrees operating temperature so it shut down. Make sure that the thermocouple is slid all the way into the ceramic cover and is up against its end. If the green light came on then the thermocouple could very well be OK because it is sensing heat.
 
Status