Electric Spliter Problem

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

shanenest

Member
Oct 1, 2008
20
MA
Have an older craftsman electric splitter, its one of those models that splits in both directions. While splitting a piece of stringy willow it kept going in one direction & even after flipping switch to make it go back in the other direction it won't. I don't know much about electrical but i would like to try to fix myself. Any idea what part needs to be replaced to make this work again? My guess is it somehow switches polarity to make it reverse directions & whatever makes that happen is fried.

thanks for looking!
 
Have a picture?
 
Sure, thanks for the help!
 

Attachments

  • Log Splitter.jpg
    Log Splitter.jpg
    88 KB · Views: 2,273
  • Log Splitter2.jpg
    Log Splitter2.jpg
    80.6 KB · Views: 1,393
I am guessing a screw (threaded rod) provides the motive force?

Chances are good that the swicth is the problem. Are you confident in your electrical skills?

Edit; Further proof that trying to burn willow is bad.
 
yes, that seems like it would be the case. It is driven by a screw. I will open up & see if i can see that switch.

i am no electrician but my electrical is okay.

Thanks!
 
Here are a few pics of the electrical components. I think its probably the switch thats bad, but not sure...any way to test with volt/amp meter? Other 2 parts are circuit & bridge rectifier.
 

Attachments

  • splitter small.jpg
    splitter small.jpg
    59.6 KB · Views: 1,102
  • splitter small2.jpg
    splitter small2.jpg
    45 KB · Views: 850
Idealy, you can jump out the motor in each direction. If they both work, it is the switch, in which case, replace it with an identical one. If you are lucky, you can figure out how to jump the motor from the motor schematic, inside or under the cover plate.
 
tough to tell from the pics, but I would say that the fact that it has a rectifier means that the motor is a DC motor. So if you switch polarity of the motor it should go the other way. I agree check / change out the switch.
 
You should be able to ring out the switch to see if it reverses the polarity of the DC going to the motor but if I were to guess I'd agree that the reversing switch is probably broken.. One other thing to check is check the DC voltage from the bridge rectifier with your meter on AC range the meter reading should be low.. Sometimes a bridge rectifier will lose half the bridge giving you half wave DC instead of full wave (essentially giving you less than ideal DC with lots of AC ripple).. The rectifier cost is peanuts compared to the switch..

Ray
 
If you have a meter:

With power disconnected, read the resistance of the two switch positions (forward/reverse). One side should be open and the other a short. Move switch position: the readings should reverse, the first should be a short and the other open. If this is not the case, you gotz yourself a bad switch.

The switch is more than likely the cause. Ray is on it with the rectifier as well, but those usually leave a smoke trail if they fry.
 
Jags said:
If you have a meter:

With power disconnected, read the resistance of the two switch positions (forward/reverse). One side should be open and the other a short. Move switch position: the readings should reverse, the first should be a short and the other open. If this is not the case, you gotz yourself a bad switch.

The switch is more than likely the cause. Ray is on it with the rectifier as well, but those usually leave a smoke trail if they fry.

I've seen rectifiers fail partially so you end up with half wave instead of full wave and no smoke etc.. If the OP lives nearby I will check it out for him if he drops by here..

Ray
 
raybonz said:
Jags said:
If you have a meter:

With power disconnected, read the resistance of the two switch positions (forward/reverse). One side should be open and the other a short. Move switch position: the readings should reverse, the first should be a short and the other open. If this is not the case, you gotz yourself a bad switch.

The switch is more than likely the cause. Ray is on it with the rectifier as well, but those usually leave a smoke trail if they fry.

I've seen rectifiers fail partially so you end up with half wave instead of full wave and no smoke etc.. If the OP lives nearby I will check it out for him if he drops by here..

Ray

If it was a partial fail then the splitter should at least make a nasty buzzing sound and it should affect both directions, not just one.
 
Contacts inside switch fail, will cause your problem. Partial failure of rectifier is a long shot. Another less obvious condition is a broken lead inside the insulation. Your power from the rectifier is fed to the 2 center terminals on the switch. The 2 sets of terminals on the edges of the switch are to the motor. polarity reversed between the 2 sets. as it works one way power is good. so need to determine which side of switch has failed. If 110ac volt input, output of rectifier is about 90v dc no load. the contacts furthest from the tip of the switch arm are the ones being used for that direction. Therefore we have isolated the problem to one set of leads from the switch. hope this helps. Chris
 