harman accentra vent pipe

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

shelbylul

Member
Jan 2, 2010
43
L.I. New York
is it normal to vent the accentra insert with 3" pipe? I thought 4" was preferred. My dealer said the 3" is what they use . I just want to be sure this is o.k.











harman accentra insert 8/09
 
How far are you venting? Are you venting straight out the wall? (Horizontal termination) or are you going out and up, or up and out? Harmans EVL guide, in there manual will tell you whether to use 3" or 4". Pipe is measured as follows.
90 degree or a T= 5'
45 degree angle= 2.5'
1 foot horizontal= 1'
1 foot vertical= .5'
A good rule of thumb is anything over 15 ft EVL to use 4". So if you have a Cleanout T to, 3 ft Vert to, 90* to, 3 ft Horizontal to, Cleanout T to, 3 ft Vert. You would have a 21' EVL and have to use 4". if that clarifies anything.
 
Masonry chimney? Are you running a liner up it, if its not?
 
I found a graph that related EFL to altitude. At my altitude the number is 8, so it does vary.
 
DAKSY said:
shelbylul said:
my paper work says two story flex liner package

Tell them you want it to be a 4" liner kit.
It's what Harman recommends.

x2, agreed, IMHO, 3" is too small for a 2 story job......go 4"
 
4" is what I recommend, and it seems like most others do also.
 
we use 4" for 100% of vert liners.
 
The insert was installed in 8/09 . My fault assuming it was 4". I just happened to stumble on fact that it's 3" when they called trying to sell me a chimney cleaning. Somehow it came up in the conversation and I questioned it and he told either way was fine.I just want to know if it''s safe and could the performance of my stove be affected. it seems to work o.k. , but i really have nothing to compare it to as far as heat output. Or, would it be wise to swap out the 4 " pipe/liner.

thanks again

Bill





harman accentra insert 8/09 install
 
2 stories is a long way for 3". I don't have an insert, but if I did, it would definitely get 4". IMHO. Did you ask if they would install the 4" liner? (If you pay the price difference from 3" to 4") Good luck.
 
Status
Not open for further replies.