Trialsguy

New Member
Jan 3, 2008
7
Oak Grove, Mo.
Hello there!
I just picked up the model posted in the title I haven't fired it up yet but I was reading through the manual and it stated a min of a 12' vertical flue, my question is, I will only have about 7' from the top of the stove up to the roof which I am replacing a wood stove and the vent is already in place. Will I have to extend another 5' up through the roof to get this stove to draft correctly? Also the manual says I can run corn by just changing the auger spacer but in the manual there is also a separate sheet with a hand written statement saying that a 50-50 mixture what are your guys thoughts on this?

Thanks
Bob
 
Thanks I will check it out. the corn question was kinda a secondary question I am more concerned about the flue issue. Not sure when I will try the corn mix. I want to make sure it will operate correctly first

Thanks

Bob
 
Thanks for the info, I fired it up last night, seemed to draft ok, I temporarily ran the 4" flue up the 8" black pipe I have for the wood stove and it didn't smoke back down but I did run it all the way up to the cap which is about 8'. I picked up a bag of pellets to use, On high it seems to run through the pellets, manual says 7lbs a hour, man that would start adding up if I was trying to heat the shop 24/7. With it being only a 62000 btu it might struggle if it was really cold outside my shop is insulated but not air tight and only with the blue insulate sheets that is 1 1/2 inch thick
 
7lbs an hour is about right. How large of an area are you trying to heat? A steady 62k running 24/7 in a "normal" stick build home could heat 2500 square feet with the proper air movement. I'm guessin you may not need to run that thing on high, or you may be able to wire it into a thermostat. Pounds per hour x btus is gonna stay pretty constant. If you run it 24/7 and barely maintain heat, thats gonna tell you about the heat loss in that area.
 