I agree. Although, being a small family run business doesn't leave as much time for the forums as I'd like. cwill, Thanks for the review...
I just talked with the homeowner and had him do some simple tests as the wind is currently blowing (though not at the same severity) and he has no...
Excellent points. The bumps at the ridge are the attic vents. If the wind is passing over the peak of the house it could be causing severe...
No topographical issues, this home is located on a prairie of sorts. According to the homeowner, the issue is directly related to the wind...
Post was edited to explain the problem that the wind is causing, thanks for pointing that out. The flue length of 13' does not include the attic,...
I'd appreciate your input on this one. The homeowner has been very patient but I want to get this fixed up for him asap. We installed this about 18...
I don't know that answer, however, here is what I do know. My chimney (simpson duratech class a) is straight through the middle of the house. About...
I'd say that 19' is too much. I've seen single wall runs that are 14-16' that have major creosote buildup near the top, just before it hits the...
Since we manufacture stoves, we buy the firebrick in pallets of 912 bricks. $15 for 6 bricks is close to the price each that we sell them.
$240 for Labor and about $60 for parts (26 Firebrick).
I figured there would be a few that would appreciate seeing a picture of this classic stove. We took it in last week to do some repair. We patched...
Yes, that is exactly what I meant. EPA stove with good primary air control should only have a damper if the chimney is too efficient. For example,...
Pipe size will not make a difference. Sounds like an outside masonry chimney to me. When you open the door to the stove do you feel cold air...
According to NFPA 211 the stove could be reduced to 12" clearance but NOT less. If the stove needs to be 15" I would guess that puts the pipe around...
This is what we have been told by the independent Lab that tests our stoves for EPA standards. 1. The calculation method is standardized. It...
Bill, What brand and model is your stove? Maybe some of the installers here could look up the manual online and share how it reads to them. I...
I just got off the phone with Omni. The short answer given was: No reduction of clearance on a stove with a listed minimum clearance of 10". I was...
I have a call into Omni Test Labratories to ask about clearance reduction. Omni is where all of the Kuma Stoves are tested for safety and...
I don't know whether or not your local building dept. uses NFPA Code 211 or not, however, it states that "After reduction, clearance shall be not...