You hit the nail on the head with that one. Last week I received a replacement controller and swapped it out only to have it do the same thing. I...
Thanks for the picture that helps. I'm going to add some kind of venting to mine and maybe a small fan if I can find a good way to power it.
This is a timely post. I just had my 3rd controller fail in 4 months on my Biomass 60. Original one lasted just over 2 seasons and failed in...
I have about a 3000 sq ft house with a 28 x 32 attached garage that I can heat with no problems using my Biomass 60 with 500 gallons of storage. I...
If you go with a regular UPS like an APC the batteries in them are sealed AGM type but those units only have an operating temp of about 105 degrees...
I used an AGM type which is a deep cycle battery also but does not put off hydrogen gases when charging and since this is in my house basement I want...
Little late on the reply but I just finished installing my Battery backup solution for my Biomass 60. I have used a Xantrex 600 watt pure sine wave...
Separate names with a comma.