FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 11"
DOUBLE-WALL STOVEPIPE........ 9"
MOBILE HOME.................. 9"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE....... 7"
DOUBLE-WALL STOVEPIPE....... 3"
MOBILE HOME................. 3"
|
B: STOVE TO SIDEWALL:
SINGLE-WALL STOVEPIPE........ 8"
DOUBLE-WALL STOVEPIPE........ 7"
MOBILE HOME.................. 7"
|
H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE...... 18"
DOUBLE-WALL STOVEPIPE...... 14"
MOBILE HOME................ 14"
|
C: CENTERLINE PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 14"
DOUBLE-WALL STOVEPIPE....... 12"
MOBILE HOME................. 12"
|
I: DIAGONAL FROM CORNER TO FRONT LOP:
SINGLE-WALL STOVEPIPE....... 53"
DOUBLE-WALL STOVEPIPE... 47-1/3"
MOBILE HOME............. 47-1/3"
|
D: CENTERLINE PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE... 21-1/2"
DOUBLE-WALL STOVEPIPE... 20-1/2"
MOBILE HOME............. 20-1/2"
|
J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE... 49-1/3"
DOUBLE-WALL STOVEPIPE... 45-1/3"
MOBILE HOME............. 45-1/3"
|
E: MINIMUM HEARTH WIDTH.... 33-3/8"
|
L: WIDTH OF FRONT EDGE..... 33-3/8"
|
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE... 40-1/2"
DOUBLE-WALL STOVEPIPE... 38-1/2"
MOBILE HOME............. 38-1/2"
|
COMBUSTIBLE ALCOVE DIMENSIONS:
MINIMUM 41-1/8" Wide X 84" Tall
MAXIMUM 36" Deep
|