FLAT WALL INSTALLATIONS:
| CORNER INSTALLATIONS:
|
A: STOVE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 12"
DOUBLE-WALL STOVEPIPE........ 5"
MOBILE HOME.................. 5"
| G: STOVE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE....... 8"
DOUBLE-WALL STOVEPIPE....... 3"
MOBILE HOME................. 3"
|
B: STOVE TO SIDEWALL:
SINGLE-WALL STOVEPIPE....... 12"
DOUBLE-WALL STOVEPIPE........ 8"
MOBILE HOME.................. 8"
|
H: CENTERLINE PIPE TO CORNER WALLS:
SINGLE-WALL STOVEPIPE...... 20"
DOUBLE-WALL STOVEPIPE...... 15"
MOBILE HOME................ 15"
|
C: CENTERLINE PIPE TO BACKWALL:
SINGLE-WALL STOVEPIPE....... 18"
DOUBLE-WALL STOVEPIPE....... 11"
MOBILE HOME................. 11"
|
I: DIAGONAL FROM CORNER TO FRONT LOP:
SINGLE-WALL STOVEPIPE... 58-1/2"
DOUBLE-WALL STOVEPIPE... 51-1/4"
MOBILE HOME............. 51-1/4"
|
D: CENTERLINE PIPE TO SIDEWALL:
SINGLE-WALL STOVEPIPE... 25-1/2"
DOUBLE-WALL STOVEPIPE... 21-1/2"
MOBILE HOME............. 21-1/2"
|
J: CORNER TO EDGE OF HEARTH:
SINGLE-WALL STOVEPIPE... 53-1/2"
DOUBLE-WALL STOVEPIPE... 48-1/3"
MOBILE HOME............. 48-1/3"
|
E: MINIMUM HEARTH WIDTH.... 33-3/8"
|
L: WIDTH OF FRONT LOP...... 33-3/8"
|
F: BACKWALL TO FRONT OF HEARTH:
SINGLE-WALL STOVEPIPE... 45-1/2"
DOUBLE-WALL STOVEPIPE... 38-1/2"
MOBILE HOME............. 38-1/2"
|
COMBUSTIBLE ALCOVE DIMENSIONS:
MINIMUM 43-1/8" Wide X 84" Tall
MAXIMUM 36" Deep
|