The Chimney Sweep Online Fireplace, Woodstove, Gas Stove and Barbecue Shop
CUSTOMER NAME __________________ STOVE MODEL ________________ ADDRESS __________________ SERIAL NUMBER ______________ DATE __________________ DATE CODE __________________ 1: LINE PRESSURE ARROW+ AVALON+ NOVUS+ HEARTH- WATER-
LOW - HIGH DOVRE AVANTI MENDOTA STONE FORD
NG __________ 4.5-7 5.5-7 4.5-10.5 4.5-10.5 4.5-11
LP __________ 11-14 11.5-13.5 10.5-13 11-13.5 11-13
2: MANIFOLD PRES. ARROW+ AVALON+ NOVUS+ HEARTH- WATER-
LOW - HIGH DOVRE AVANTI MENDOTA STONE FORD
NG __________ 1.7-3.5 1.0-3.5 1.5-3.5 1.5-3.5 1.5-3.5
LP __________ 5.4-11 2.7-11 3-10.5 2.5-10 2.5-10
3: DETERMINE WIRING PROPERLY CONNECTED TO GAS VALVE (CHECK): THERMOPILE IS CONNECTED TO SCREWS #1 & #2 (TH/TP & TP) _____
THERMOSTAT IS CONNECTED TO SCREWS #1 & #3 (TH/TP & TH) _____
ALL FITTINGS CLEAN AND TIGHT _______
4: THERMOSTAT WIRE IS PROPER SIZE _____ WIRE SIZE MAX. LENGTH
14 GA. 100 FT.
16 GA. 64 FT.
18 GA. 40 FT.
20 GA. 25 FT.
22 GA. 16 FT.
5: MILLIVOLT SYSTEM TESTS (FILL IN READING): AVALON/ ALL
AVANTI OTHERS
SYSTEM: BURNERS LIT, 2(TP) & 3(TH) _______ >125 >100
OUTPUT: PILOT ONLY, 1(TH/TP) & 2(TP) ______ >350 >325 RESISTANCE: BURNERS LIT, 1(TH/TP) & 3(TH) _____ <80 SAME EPU CURRENT TEST: PILOT LIT, 2(TP) & EPU _____ >125 SAME 6: SPILL SWITCH TEST:
SET GUAGE TO TONE; DISCONNECT TWO WIRES FROM SPILL
SWITCH, TOUCH ONE PROBE TO EACH WIRE. TONE INDICATES
WIRING TO SPILL SWITCH IS OK. ______ (CHECK IF OK)
7: EXHAUST CONNECTOR AND CHIMNEY FLUE ARE CLEAR _________
8: PILOT AND BURNER ORIFICES ARE CLEAR ________
9: BURNER OPENINGS ARE CLEAR________
10: AIR SHUTTER IS PROPERLY ADJUSTED__________
11: NO LEAKS DETECTED IN APPLIANCE, SUPPLY LINE OR EXHAUST SYSTEM ________
|