Bought a used Santa Fe, wired around vacuum switch?

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.
My Contour runs on HIGH mode only.
It runs sometimes on medium mode. I think you guys are right about CSS syndrome.

This stove for many years did run fine on medium. I have cleaned it from top to bottom and is running much better.
Also replace the vacuum switch.
If you're trouble shooting a vacuum problem do not blow an air can in the hose toward the vacuum switch. You will blow out the switch! I know this for a fact.

I plan on adjusting the pot dump plate. I believe it is a little too lose.

As these stoves get older, soot gets in the void aft of the exhaust fan and before the rear pipe coupling. This is a bear of a place to clean unless you remove the exhaust blower.

The Contour is an older model, but doesn't mean that it has CSS.

Also, the Combustion blower should be removed at least once a yr (the area you need to clean) according to the manual

As for CSS, some older Quads (Contour, 800, 1000, etc) did start up in the heat level selected (opposed to the New Quads starting in High, regardless of heat setting). But that Does Not mean that the older units wont start on Low or Medium
All the new Heatilators run just like the Older Quads. They start up in the heat setting they are on, just as the old box stoves. They start fine as does any other stove that is clean, has a good ignitor, clean vent, maintained motors and.blowers, and feed rate set correctly.

CSS is a made up term, related to this site only.

Stovers, CSS is BS IMHO....... :p If it 'used' to work OK, then it suddenly doesn't get CSS Syndrome. Something changed. These stoves have a lot of variables that affect how they run. Length of pellets and pellet density are often overlooked as a cause of problems. If you have the feed gate set for small pellets and you get a bag of longer pellets, suddenly you are feeding less lbs/hr and either it doesn't get enough pellets to start or the heat is less than you expected. That's just one example of how some people can blame CSS as a viable cause of problems.
 
CSS, Ah yes. Know it well. My little 800 also suffer from it. Seeing it resided in a cool basement was deemed the issue. My work around was add 1 to 2 extra hand fulls of pellets to the pot before I fired it off. Seemed to fire every time, But what fire it had. Sound of it would startle you once it got rolling and lots of smoke too. But it worked. Mine didn't seem to be vacuum related. It was not getting the thermal couple hot enough. Wasn't a speed thing either. It only had one speed(hi).

Can't really knock it as it kept us warm for 9 seasons and no major parts. I did change the convection 160º snap disk, But later found a hidden chamber that had an ash build up. Kept the old one for a spare. She served us well, Just needed to be in a warmer place.
 
1k to 1500.00 around here in good shape.
I just had a test fired only Lennox Montage shipped up from MO from a dealer for less than that last week.
 
The Contour is an older model, but doesn't mean that it has CSS.


CSS is a made up term, related to this site only.

CSS of Cold Start Syndrome is not made up! Sure if the house the stove is in, never goes below 50 degrees then, you will not see the problem. The problem is that for stoves that do not run their exhaust fans on high during the start up cycle have a very hard time starting when the temp is below 30 deg f. I have seen this problem first hand. At 30 Deg F or below there is not enough vacuum to keep the auger turning during the start up cycle. That is a real problem with stoves in a cabin, shed or a very cold basement!
 
Good news!
I replaced the vacuum switch and the rope gasket.
And I gave it a real good cleaning.

Most important I used a Spray Creosote remover.
This stuff is awesome. I sprayed it in every nook and cranny in the pot, firebox and exhaust fan.
When the stove hits 500 degrees it blows all the soot out.

It cleaned out the void area aft of the exhaust blower. On start up, it has that little whistle when the pellets start burning.
Have not heard that in a awhile. And a real good low rumble when fully running.

Runs like a brand new stove.
;)
 