Shaw520

Feeling the Heat
Oct 15, 2012
426
Modena
...the old Englander was cranking along nice today, then for no apparent reason the convection fan quit, should I assume its the blower motor!,...there is a Graingers not far from here that I can probably get a new motor on monday,

... btw .. stove kept operating as normal without the fan.
 
...the old Englander was cranking along nice today, then for no apparent reason the convection fan quit, should I assume its the blower motor!,...there is a Graingers not far from here that I can probably get a new motor on monday,

... btw .. stove kept operating as normal without the fan.
Greg,

could be a bad motor or a bad snap switch. test it like Imacman suggested:)
 
Greg,

could be a bad motor or a bad snap switch. test it like Imacman suggested:)
There are no snap switches on Englanders, control board send signal when stove reaches temp...maybe check the OAT On Air Temp that is a delay on start up 1 is right away, 9 is later on...make sure its not on zero or it will not come on at all
 
The diagnostic mode is the easiest check, but can't separate blower failure from triac failure. Easy to try though.
You could wire the blower to where the igniter normally goes and see if it turns on at startup. Then you know if it's the triac or the blower.
An inspection of wires might be appropriate, I have seen crimps cut through wires that then fail due to vibration.
 
Thanks for all your ideas,.. I pulled it apart and found the outside bearing on the blower motor fried (seized up)... I replaced both bearings,.. cleaned the blower assembly and reassembled the motor,.. she working normal once again.