Do I have a creosole problem or is this normal?

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

MoBigs

New Member
Nov 28, 2012
9
Hello Everyone,

I'm pretty new on the site and have been reading lots of the threads here and finding valuable information which is fantastic. I even built a rail kit for my Harman Accentra Insert with instructions found in this thread from glenc0322. Thanks again glenc0322!

So after tackling the Harman Accentra that is in our family room on the main level of my house, I've moved on to the Harman P38 I have in my basement where I spend a lot of time in my home office.

In the process of cleaning the P38, I took the opportunity to snap a few photos of some spots that have some creosole buildup. I'm not sure if I've got a problem or if this is normal? I've always had the "year end" cleaning done by a local business, but I'm trying to save some money (I know, welcome to the club) so I'm starting to do the year end cleaning myself. Thanks ahead of time for bearing with me. :)

Here are the "potential" problem areas. I would love your feedback on whether I should be worried about this or not?

I've only burned New England Premium Wood Pellets in this stove and the Accentra.

Burn Pot
IMG_0014_zps1471823d.jpg


IMG_0013_zpsb0735b46.jpg


Top Left Corner

IMG_0017_zps0ea5eea9.jpg



Top Right Corner

IMG_0028_zps4dff9405.jpg




Backside of bottom door where you access the ash pan.

IMG_0023_zpsfa5ccb15.jpg



Close Up

IMG_0024_zps2acbf281.jpg


Blower Cover Latch (behind ash pan)
IMG_0027_zps194aa135.jpg


Thanks Guys!
 
Some people say there shouldn't be any creosote and you have a problem. I have a P68 and have creosote build up in those exact areas. I do not have a problem until the end of the year after I've burned on low for awhile. My stove burns fine so I'm not that concerned. When we had a warm spell recently, I took a putty knife and it was like cutting butter, it came right off.
 
  • Like
Reactions: gbreda
Hello

I have seen worse, yours is not bad. If you have an OAK (Outside Air Kit) and live in a damp area. (By a lake, ocean or there is morning dew) Then the OAK will bring that damp air into the burn pot and exacerbate the ash build up. Only a system that warms and dries out the burn air like Selkirk DT venting can vastly improve that.
 

Attachments

  • IMG_0435.JPG
    IMG_0435.JPG
    200.6 KB · Views: 432
.....the OAK will bring that damp air into the burn pot and exacerbate the ash build up. Only a system that warms and dries out the burn air like Selkirk DT venting can vastly improve that.
We've had this discussion before. There is no proof or data that confirms this. There is no guarantee that using the DT venting will help this, unless you've found new "proof".
 
  • Like
Reactions: Delta-T
We've had this discussion before. There is no proof or data that confirms this. There is no guarantee that using the DT venting will help this, unless you've found new "proof".


It helped tremendously in my situation, and I hear it is more of an issue in the North East from one of my National Sales managers.
 
  • Like
Reactions: iceguy4
how frequently do you clean the area under the burnpot? looks like you're burning a lil bit rich, so it could be moisture, but more likely some airflow restriction somewhere...when you have no igniter its easy to "delay" cleaning that area. Add to that the running on low for a while at the end of the season and I think you'll get what you have there. I say no worries...is not tha bad. P38 is super tough...like Rocky in Rocky1 and 2....maybe Rocky 4 (that was the one with Dolf right? "I break you"...but he didn't).
 
  • Like
Reactions: stoveguy2esw
not something i would worry about.
 
Exactly like my P-38 after extended low burns in the fall and spring. It will however burn off quickly after a hotter burn .
After 7 yrs use I pulled (replaced) the auger ,and cleaned the tube back to the slider plate. I found creosote well past the second flight and what I thought could lead to back burn (eventual hopper fire)?
Low burning a P-38 creates a hot burn at a lower level nearer the tip and auger tube . I believe it was the cause of why the auger tip disintegrated.
Anyway , I think low burning isn`t exactly an ideal burning situation but the P-38 lacks auto start so you don`t have a lot of options but to turn it down when it`s not real cold. Like everything else in life, there is a compromise somewhere.
 
  • Like
Reactions: MoBigs and gbreda
Mine did that on certain brands of pellets, Green Supreme, and I think it was Geneva.
 
Thank you very much for all the feedback guys. I'm thinking based on all of the responses, my issue is a combination of running the stove on low at the end of the season and possibly a bit of restricted air flow due to a good cleaning needing to be done. I'm going to finish giving it a good cleaning and keep an eye on it when I fire it up this fall. I really appreciate the responses and look forward to learning more from you all of you.

Mo
 
Did my deep clean and cap off 2 days ago. Same thing in the same places. Happens after the final month or so of burning where I might burn 2-3 times max and they are low burns for a short time with humidity on the rise. If you want to get rid of it, fill the hopper, crank it up an burn it off- then hide from the family because its so hot in the house :). Dont worry about it. Clean and cap it off from the humidity.

BTW, after my first 2 years of just capping the exhaust vent and resulting in some rust in the firebox, I now plug EVERYTHING with rags and store the firebricks in the ash pan outside of the stove. Outside vent gets capped, rags in OAK intake tubing or at the stove intake port (probably the biggest help here), exhaust tube behind ash pan, exhaust at the T AND 2 tubs of Damp Rid in the firebox (1 in the burn pot and 1 in the ash pan area). Overkill yes but bone dry ! Just remember to take all of these out in the fall ;)
 
Too low a vent temp, will creosote the vent pipe. I think Eric said it needed to be at least 165 deg F, or something like that.
 
Did my deep clean and cap off 2 days ago. Same thing in the same places. Happens after the final month or so of burning where I might burn 2-3 times max and they are low burns for a short time with humidity on the rise. If you want to get rid of it, fill the hopper, crank it up an burn it off- then hide from the family because its so hot in the house :). Dont worry about it. Clean and cap it off from the humidity.

BTW, after my first 2 years of just capping the exhaust vent and resulting in some rust in the firebox, I now plug EVERYTHING with rags and store the firebricks in the ash pan outside of the stove. Outside vent gets capped, rags in OAK intake tubing or at the stove intake port (probably the biggest help here), exhaust tube behind ash pan, exhaust at the T AND 2 tubs of Damp Rid in the firebox (1 in the burn pot and 1 in the ash pan area). Overkill yes but bone dry ! Just remember to take all of these out in the fall ;)


Ok, so another new thing I'm picking up on from this reply is that I should I should be "capping" my stove and... I should be putting "Damp Rid" in the firebox and burnpot... I've NEVER done either of these things. _g By "capping", I'm guessing from what you've described, you are essentially sealing off any opening that leads to the firebox by stuffing a rag into that opening... correct?

Should you do this with any stove when it's not in use on a seasonal basis?
Thanks,
Mo
 
Ok, so another new thing I'm picking up on from this reply is that I should I should be "capping" my stove and... I should be putting "Damp Rid" in the firebox and burnpot... I've NEVER done either of these things. _g By "capping", I'm guessing from what you've described, you are essentially sealing off any opening that leads to the firebox by stuffing a rag into that opening... correct?

Should you do this with any stove when it's not in use on a seasonal basis?
Thanks,
Mo

Yes, if you are in a damp/humid area then it should be capped. My exterior vent is capped with a rubber end cap and secured with a hose clamp. If you have an OAK, that should be plugged as well.

The rags I refer to are all internal. As I mentioned its overkill, but I have no more rusting since doing this.
 
Yes, if you are in a damp/humid area then it should be capped. My exterior vent is capped with a rubber end cap and secured with a hose clamp. If you have an OAK, that should be plugged as well.

The rags I refer to are all internal. As I mentioned its overkill, but I have no more rusting since doing this.


Ok well... I have plenty of rags around, I just need to go find some damp rid...

Thanks again to all of you for your advice/help, much appreciated!
 
Ok well... I have plenty of rags around, I just need to go find some damp rid...

Thanks again to all of you for your advice/help, much appreciated!

Ahhh, just realized you have an insert. So yes, if you slide the unit out and plug the intake and exhaust ports with rags, you should be all set. Damp Rid in the firebox (some put in the hopper as well) will seal the deal.

Just remember to remove the rags before firing up in the fall ! ! :)
 
We've had this discussion before. There is no proof or data that confirms this. There is no guarantee that using the DT venting will help this, unless you've found new "proof".


Hi Pete
We found a better reason in another post
Selkirk DT does warm the fresh air coming into the burn pot. So there is no cold air mass meeting the warm moist air mass in the stove to produce rain! That is an exaggeration but no moisture precipitates out causing the ash to stick together like the ash turds in the Harman burn pots. These turds are on each side because that is where the cooler OAK air meets the warm moist air around the fire! With Selkirk DT there is no cold air to cause the moisture to precipitate out causing the ash to not stick together!

In the case of my Astoria being in a basement, the caked ash at the bottom of the burnpot is where the cooler moist air from the OAK met the warm moist air under the burn pot so moisture precipitated out causing the caked ash! After the Selkirk DT install, no more caked ash!
 
Some people around here seem to have the opinion that Selkirk DT is better for your stove than other venting... It is not. It doesn't dry out air coming in and it doesn't do anything to improve combustion than installing a regular OAK would do. Yes, cut one very much bigger hole... That's the feature and benefit, all in one.
 
Some people around here seem to have the opinion that Selkirk DT is better for your stove than other venting... It is not. It doesn't dry out air coming in and it doesn't do anything to improve combustion than installing a regular OAK would do. Yes, cut one very much bigger hole... That's the feature and benefit, all in one.


You are correct Scott it does not dry the fresh air, but it warms the fresh air coming in so you do not have a cold air mass from outside coming in contact with warm air inside, creating rain. Well rain is an exaggeration but some moisture precipitating out causing the ash to stick together more. I must say it only happens when running the stove on low heat settings and on damp early mornings. So many people are not effected and may not see that problem. Also, I have seen that problem more on stoves with a manual damper rod and more on stoves installed in a basement where the air can be more damp.
 
You are correct Scott it does not dry the fresh air, but it warms the fresh air coming in so you do not have a cold air mass from outside coming in contact with warm air inside, creating rain. Well rain is an exaggeration but some moisture precipitating out causing the ash to stick together more. I must say it only happens when running the stove on low heat settings and on damp early mornings. So many people are not effected and may not see that problem. Also, I have seen that problem more on stoves with a manual damper rod and more on stoves installed in a basement where the air can be more damp.
What you are explaining about warm air and cold air makes no sense. Warm air and cold air don't make rain. In extreme conditions it may make wind. Rain from air masses is totally different and has to do with saturation and depressurization. Dude, were talking about air going through a tube at a pretty good clip to it's final destination in the burn pot. Let's just say for example that the air coming in was 50::F and the exhaust going out was 300::F...and let's say that the air coming in was actually able to heat up...what? 5::F? 20::F? ...that would also mean that the exhaust was able to cool even more...Sounds like a creosote problem in the vent...wouldn't ya say?
 
Status