Not sure that this a good or bad idea.
Something needs to open to relief the pressure. If not, the pressure will look for the next weakest point and maybe do some more severe damage.

In Austria/Germany they install a device in the chimney near the boiler that has an "explosion cover"
It is typically integrated in the barometric damper T.
The explosion cover is spring loaded.
So it releases the pressure and then closes again.
This all happens in a fraction of a second.
I will see that I can find a picture.

Also, in Europe (Italy), many pellet boilers have a similar spring loaded cover integrated in the boiler body to prevent this when pellet ignition failed and lots of wood gas is present in the fire box and suddenly ignites.
 
  • Like
Reactions: raybonz
Not sure that this a good or bad idea.
Something needs to open to relief the pressure. If not, the pressure will look for the next weakest point and maybe do some more severe damage.

In Europe they install a device in the chimney near the boiler that has an "explosion cover"
It is typically integrated in the barometric damper T.
The explosion cover is spring loaded.
So it releases the pressure and then closes again.
This all happens in a fraction of a second.
I will see that I can find a picture.

Also in Europe, many pellet boilers have a similar spring loaded cover integrated in the boiler body to prevent this when pellet ignition failed and lots of wood gas is present in the fire box and suddenly ignites.
Good points there.. Obviously something needs to be done as what is there now is not acceptable.. What happens pretty much sounds like a backpuff which my CDW stove was notorious..

Ray
 
Thanks. I have no idea why the photos are repeated, I uploaded just two. Sorry about that. Would you know how to correct?
Try editing your post.. Edit is located at the bottom of your post..

Ray
 
I fixed it.
 
Some pictures of an explosion cover integrated in a barometric damper.

The reason the door blows open is because it's pressure on a flat surface.
If the door does not open, then the pressure will most likely act on the next weaker flat surface; boiler water jacket, .... .
 

Attachments

  • photoA.JPG
    photoA.JPG
    201.4 KB · Views: 129
  • photoB.JPG
    photoB.JPG
    158 KB · Views: 143
  • photoC.JPG
    photoC.JPG
    227.4 KB · Views: 146
  • photoD.JPG
    photoD.JPG
    165 KB · Views: 153
  • photoE.JPG
    photoE.JPG
    218.2 KB · Views: 152
  • Like
Reactions: raybonz
Storage is move a convenience item than anything else. I couldn't heat with wood if I didn't have it due to work schedule, however. So for me it's a necessity and it works flawlessly.
Storage also eliminates idling, which can help keep your fire tubes from accumulating creosote (less tube punching). :)
 
  • Like
Reactions: hobbyheater