Look for pellet stove parts on ebay and you should fall upon the vendor who sells them.
 
Was getting hard to find the off. Stove had been off over night only to come in in the morning to find the stove running. The switches only have so many cycles-on off.
 
That explains why mine doesn't shut down. I replaced only my temp knob when I did mine. Mine does go in shut down mode but the exhaust fan stays on forever. I'm sure it could be the board acting up, it wasn't the esp.
 
Considering that once your pulling the switches off, it's only about ten minutes, it's really not a big deal to do them all.
 
Was getting hard to find the off. Stove had been off over night only to come in in the morning to find the stove running. The switches only have so many cycles-on off.
Fairly ridiculous that Harman puts such cheap pots in there. My new 68 has a detent in the off position, whereas my 2012 P38 didn't. I wonder if they're using a different pot now.
 
100k, just about all harmans take the 100 but the p38 takes 50k. I just punched in Harman pellet stove in ebay and scrolled till they popped up.
 
Its sounds like my stove starting up on its own when in off. They are $9 for the set of three. A new ESP is $50. What is the visit from the dealer? A visit from any pro in my area is $70 to knock on the door.
 
Had to pull the plug on my stove the morning the dealer replaced the ESP. Kept feeding. IIRC, the stove will feed a small amount on shut down IF the stove was coming off being run hard. I believe it does this to allow the burning mass of pellets in the pot to cool down, preventing excessive burn back through the auger tube. My faulty ESP was reading ALL over the place, so despite the knob being in the off position, it kept feeding "thinking" it was still ripping hot. After the ESP replacement, all is good....including the erratic distribution fan issues mentioned in others recent threads.
 
I just finished taking the whole stove apart and giving it a real good cleaning. I'm going to try one last stich effort. Then start throwing parts at it. Will let you know how I make out. Thanks all for the input.
I run it for 3 years and only had to replace the dist. Blower so I guess that's not too bad.
 
Distribution after 3 yrs?

They should last a lot longer than that.
Do you have pets?
 
You might get a lot of cat hair buildup on the back of the (II believe combustion blower) on the back left side..it can easily get coated with hair which really blocks flow.
 