Hello Everyone:

I spent several months trying to buy a gasket for the Piazzetta Smoke Chamber Cover with no luck. The distributer sent what they thought was right but it was too thick and with the tolerances so narrow on the cover it wouldn't fit. Finally the word came back that Piazzetta doesn't make the gasket any more, with the suggestion that a hi-temp RTV silicone caulking be used. Here are the instructions the distributor sent:

"A thin layer of high temp RTV silicon (sic) approximately 1/32-1/16” x3/8” be applied to the cover door perimeter and allowed to cure for several hours. After the silicon is cured the cover can be reinstalled."

My guess is letting it cure unmounted is to facilitate future removal.

I found 2 hi-temp ones, one good up to 450˚ and the other to 650˚. I used 650˚.

Hope this helps anyone in the same predicament.

Cheers, BillX
 
SF_Maintenance_Gaskets_FiberglassGasketTapeKit_medium.jpg

I used this product, it was bit of a tight fit but it works.
 
  • Like
Reactions: shirwood
Hello Everyone:

I spent several months trying to buy a gasket for the Piazzetta Smoke Chamber Cover with no luck. The distributer sent what they thought was right but it was too thick and with the tolerances so narrow on the cover it wouldn't fit. Finally the word came back that Piazzetta doesn't make the gasket any more, with the suggestion that a hi-temp RTV silicone caulking be used. Here are the instructions the distributor sent:

"A thin layer of high temp RTV silicon (sic) approximately 1/32-1/16” x3/8” be applied to the cover door perimeter and allowed to cure for several hours. After the silicon is cured the cover can be reinstalled."

My guess is letting it cure unmounted is to facilitate future removal.

I found 2 hi-temp ones, one good up to 450˚ and the other to 650˚. I used 650˚.

Hope this helps anyone in the same predicament.

Cheers, BillX
to be honest with you I don't even use a gasket I have adjusted the stove with out it and it does work fine as long as your cover is not warp but hi temp silicone is a good idea too
 
  • Like
Reactions: shirwood
to be honest with you I don't even use a gasket I have adjusted the stove with out it and it does work fine as long as your cover is not warp but hi temp silicone is a good idea too

Pascal: Thanks for the input. I thought of that and if I couldn't get the silicone, that was my next option. It's a matter of wait and see now. I'll lift it next year and if it causes grief, I'll do as you do. I'm assuming you didn't notice any more ash in the chamber with no gasket.

BillX
 
  • Like
Reactions: shirwood
Pascal: Thanks for the input. I thought of that and if I couldn't get the silicone, that was my next option. It's a matter of wait and see now. I'll lift it next year and if it causes grief, I'll do as you do. I'm assuming you didn't notice any more ash in the chamber with no gasket.

BillX
yes I do have ash in it but since there is no gasket to rattle with I clean it more often it is so easy and it does not interfere with the air path. I Just make sure that there is no ash or dust that could make a gap.

regards
 
If I remember the gasket material for the access plate was the same as the glass gasket ,self adhesive RP00501000RZ

Later