New to stoves, please help me

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Nat gas is almost always the better choice,right now.
I hear you, i guess I should have done a little more homework but the machine said up to 25hours a burn, i trusted it and did my math accordingly, thinking I could set it at its lowest setting at night to save on costs. You live and learn I guess.
 
I hear you, i guess I should have done a little more homework but the machine said up to 25hours a burn, i trusted it and did my math accordingly, thinking I could set it at its lowest setting at night to save on costs. You live and learn I guess.
It is good you are doing the research,many do not and end up dissatisfied.:)
 
Check the bottom 3 numbers (buttons below heat and blower buttons)

Also check what mode your stove is in. Should be set to D mode.

A quick search on this site for englander 25pdvc will provide tons of information.

I have the same stove and use a bag about every 22 hours on medium heat settings.

Sent from my SM-G950U using Tapatalk
Man is i can get that il be one happy duckling. I have the three options under blower speed and heat range setting that I cant figure out what they do. Couldnt find it in the manual and my adhd is making it even harder haha.
 
Sorry was trying to I sert a link to another thread but not working.

I copied the post:
Check to see what mode it's in. factory should be D

Checking / setting the Heat Mode
Heat Mode, the default setting is 'd' for the 25-PDVC, and for the 25-PDV it is 'c', but some control boards default to 'A' when a reset is done. Do not run the stove in 'A' or 'b' mode.
Unplug the stove from the mains.
Plug power lead back in and press both the up and down blower speed buttons at the same time within 4 - 5 seconds and then release the buttons, you should now see a letter (A, b, c or d) in the left or right digital display under heat range or blower setting, you need to change this to 'd' or 'c' using the up / down buttons below that readout, or in case of the 25-PDV you need to use both buttons up or down, once set to 'd' or 'c' wait 10 - 15 seconds then unplug the power again and wait 5 seconds. (Sometimes the mode that you want does not set and defaults back to the mode that it was in before, repeat this step to make sure the mode that you want is set.)

The 3 lower buttons factory settings for the 25-PDVC should be
LFF = 6
LBA = 4
AOT = 1

Note: The 25-PDVC can be run in mode 'c'. Never run the 25-PDVC in 'A' or 'b' mode.

Sent from my SM-G950U using Tapatalk
 
  • Like
Reactions: Mt Bob
Sorry was trying to I sert a link to another thread but not working.

I copied the post:
Check to see what mode it's in. factory should be D

Checking / setting the Heat Mode
Heat Mode, the default setting is 'd' for the 25-PDVC, and for the 25-PDV it is 'c', but some control boards default to 'A' when a reset is done. Do not run the stove in 'A' or 'b' mode.
Unplug the stove from the mains.
Plug power lead back in and press both the up and down blower speed buttons at the same time within 4 - 5 seconds and then release the buttons, you should now see a letter (A, b, c or d) in the left or right digital display under heat range or blower setting, you need to change this to 'd' or 'c' using the up / down buttons below that readout, or in case of the 25-PDV you need to use both buttons up or down, once set to 'd' or 'c' wait 10 - 15 seconds then unplug the power again and wait 5 seconds. (Sometimes the mode that you want does not set and defaults back to the mode that it was in before, repeat this step to make sure the mode that you want is set.)

The 3 lower buttons factory settings for the 25-PDVC should be
LFF = 6
LBA = 4
AOT = 1

Note: The 25-PDVC can be run in mode 'c'. Never run the 25-PDVC in 'A' or 'b' mode.

Sent from my SM-G950U using Tapatalk
Good catch.He can always search "england bottom settings" or stove model number bottom settings,lots here about that.
 
THANks guys, im gonna try the fine tune, have some hope again. “
The 3 lower buttons factory settings for the 25-PDVC should be
LFF = 6
LBA = 4
AOT = 1

How do I see those adjustments? Pressing those bottom three buttons to adjust those numbers didnt do anything if I remember correctly. Wish this was in the manual
 
Last edited:
When the stove is on press each. Button and it will display the number it is set at
 
Use the ^ v arrows to change them
 
I think im gonna have to come out there and show ya lol;)
 
I was noping i could edit that part out before someone caught it lolol, ssyko youre too dang quick for me tho lol. Ok everything is set and the three bottom numbers were all set to 9 except lower feed which was 7..... seems high compared to the numbers givin. Shes powering back on now, il post results tomorrow. Thanks for the help
 
Wowyour last number should always be 1
 
:)
 
Ok just an update, it was 32 out and my back rooms were 63 and my living room was 70 with the 5-9 setting.Kept it at 3-9 for 12 hours and 7 hours on 5-9. Got 19 hours this time. The impingement plate still was incorrectly positioned so I just got that squared away. Im using “green supreme” pellets and after some research everyone is saying there shyt. That would account some for the low heat ive been getting. Il be getting in touch with my local pellet stove store to see what they stock after the holiday.. happy turkey day everyone. Updates to come
 
Last edited:
  • Like
Reactions: Mt Bob
Your dialing it in now bud. Happy Thanksgiving to you and your family
 
  • Like
Reactions: Doylee4693
Green Supremes can heat the house but it will take more pellets to do it and build more ash as a result. They work in a pinch and they work in shoulder season. They suck when the weather actually turns cold.
 
well i wanna set one of my skeletons free, when i put my wall thimble in from inside to the outer brick wall there was about a inch or two gap, will this be a prob?
 
Last edited:
well i wanna set one of my skeletons free, when i put my wall thimble in from inside to the outer brick wall there was about a inch or two gap, will this be a prob?
If it was me for piece of mind I would extend it to meet the brick tightly or overlap the other half of the thimble. Code wise there should be no gaps inside the wall. Sorry it may not be what you want to hear but it’s better to be safe then burn your house down
 
  • Like
Reactions: cecil_archer
No 7” vent in town to match the thimble, i slaughtered the other side of thimble with tin snips so i could t use that even if I wanted to.. its gonna be a pain in the rear doin this i can already feel it
 
No 7” vent in town to match the thimble, i slaughtered the other side of thimble with tin snips so i could t use that even if I wanted to.. its gonna be a pain in the rear doin this i can already feel it
I had the same issue when I did mine . It’s simple, just get a piece of sheet metal and make your own by wrapping around the thimble and sheet metal screws or find a larger piece of gauge duct and do the same. Your just making a heat shield.