Harmon ESP code but still operating

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
I never sold Harman and have only worked a dozen or so.
I'm am no expert.
Just received a call from homeowner that I serviced last year.
He said after 20 minutes the ESP code is fashing but stove is still operating normal.
I told him to clean the combustion chambers and brush off ESP and be sure the room temp sensor wires are connected to stove.
Any ideas.
 
I never sold Harman and have only worked a dozen or so.
I'm am no expert.
Just received a call from homeowner that I serviced last year.
He said after 20 minutes the ESP code is fashing but stove is still operating normal.
I told him to clean the combustion chambers and brush off ESP and be sure the room temp sensor wires are connected to stove.
Any ideas.
The ESP flashing is cause by the probe going out of range, either High or Low. If there is a port for the DDM on their control board you might see the ESP probe temp. spiking and lowering. shutting the stove down on its own and unplugging the stove will reset the board. Sometimes the probe is to far gone and will need to be replaced. I have see it in a number of stoves. My P61 will flash even through it is running fine, I shut the stove down, pull the probe clean it off, plug back in, start it up and no more flashing.
 
The ESP flashing is cause by the probe going out of range, either High or Low. If there is a port for the DDM on their control board you might see the ESP probe temp. spiking and lowering. shutting the stove down on its own and unplugging the stove will reset the board. Sometimes the probe is to far gone and will need to be replaced. I have see it in a number of stoves. My P61 will flash even through it is running fine, I shut the stove down, pull the probe clean it off, plug back in, start it up and no more flashing.
Thanks
He called back said he brushed off prope and it's no longer flashing.
Stove was working just flashing