Question on loading stove

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.

Itslay90

Feeling the Heat
Dec 16, 2022
425
Upstate,NY
What’s the best way to load your wood stove. stacking or packing it tight. With little bit of air can get to the wood.Which one gives you better heat.
 
What’s the best way to load your wood stove. stacking or packing it tight. With little bit of air can get to the wood.Which one gives you better heat.
It depends what you want. Loosely staked will generally give you more heat faster while tightly packed will give you the longest burn
 
It depends what you want. Loosely staked will generally give you more heat faster while tightly packed will give you the longest burn
Thank you, I been loading pack this whole time, and I noticed it just maintain the temperature, but when I load loosely that’s when It gives me the most heat
 
More air and more surface area burning. But it will be a considerably shorter burn
And a potentially higher risk of overfiring the stove, especially if the draft is strong.
 
  • Like
Reactions: bholler
So how much should it be closed!
As far as is possible without smoldering the fire. The air control is not linear, most of the fine control is in the last 25%. On our stove which has the same firebox as yours, the air control is typically closed down to about 5-10% open once the fire is burning strong, or maybe 1/4" from fully closed. If the draft or fire is very strong it gets closed down all the way. The fire still burns well in that case. As long as the flame does not go out and/or the fire starts to smolder, the air can be reduced quite far. There is still air being fed to the fire via the boost air, air wash, and secondary air.
 
  • Like
Reactions: bholler
So how much should it be closed!
That will vary from setup to setup but I would bet you are wasting much of your heat up the chimney. What pipe temps are you running at
 
As far as is possible without smoldering the fire. The air control is not linear, most of the fine control is in the last 25%. On our stove which has the same firebox as yours, the air control is typically closed down to about 5-10% open once the fire is burning strong, or maybe 1/4" from fully closed. If the draft or fire is very strong it gets closed down all the way. The fire still burns well in that case. As long as the flame does not go out and/or the fire starts to smolder, the air can be reduced quite far. There is still air being fed to the fire via the boost air, air wash, and secondary air.
Okay, I’m going to load right now and try that. I’ll keep you posted it on that.
 
 
  • Like
Reactions: bholler
So where should it be at? begreen said let it stay at 350 or lil bit under ?
Reread the thread. I suggested trying to keep the flue temp at or below 350º regardless of the stovetop temp.

The flue temperature varies. It is going to be high when starting up the fire, but as the air is closed down to cruising level, it will drop. Each stove and each fire is going to vary a bit depending on the fuel, draft strength, how it is loaded, and how the stove's air control is run. With the air mostly closed, or close to it, our stove settles in typically with a 600-650º stove top temperature and a similar flue temperature.
 
Reread the thread. I suggested trying to keep the flue temp at or below 350º regardless of the stovetop temp.

The flue temperature varies. It is going to be high when starting up the fire, but as the air is closed down to cruising level, it will drop. Each stove and each fire is going to vary a bit depending on the fuel, draft strength, how it is loaded, and how the stove's air control is run. With the air mostly closed, or close to it, our stove settles in typically with a 600-650º stove top temperature and a similar flue temperature.
That is flue temp of 600 to 650 internal. So 300 or so surface. I shoot for 250 surface for best efficency
 
That is flue temp of 600 to 650 internal. So 300 or so surface. I shoot for 250 surface for best efficency
Okay I’m aiming for that right now, this is how my fire is burning right now. This is how it’s supposed to burn ?
 

Attachments

  • 70148209070__640B56BB-19FA-43A3-B848-66819E89695D.MOV
    842.4 KB
Okay I’m aiming for that right now, this is how my fire is burning right now. This is how it’s supposed to burn ?
That doesn't look like much of a load at all.
 
Okay I’m aiming for that right now, this is how my fire is burning right now. This is how it’s supposed to burn ?
The fire looks ok. What is the air control position?

The wood in this fire has a ton of air circulating around it. That's the way I might burn it in late spring when I just want a short morning or evening fire. It's not representative of a full-load winter fire.
 
That doesn't look like much of a load at all.
The fire looks ok. What is the air control position?

The wood in this fire has a ton of air circulating around it. That's the way I might burn it in late spring when I just want a short morning or evening fire. It's not representative of a full-load winter fire.
Okay, when it goes down I’m going to load it pack and tight, the “ air control was under “L”
 
Okay, when it goes down I’m going to load it pack and tight, the “ air control was under “L”
Under "L" doesn't translate well. Our stove has no markings. How close to closed is/was the air control?