New guy DIY heat storage and MB55 Solo plumbing

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Yes, surface mount probes for temp readings. Buy the cheapo ones from Ebay and roll with it. I think I have about 100 bucks in all of this.
 

Attachments

  • 20171203_181403_1512346505272_001.jpg
    20171203_181403_1512346505272_001.jpg
    91.2 KB · Views: 295
Zoro box showed up today and some supply house parts too. Finalized my cold return set up. Left tank will be the same but I’ll have a union fitting in there somewhere.

1-1/2” tank to tank then 1-1/4” going up.

3/4” boiler drain on the 90 so if I need to drain these I won’t have an issue. Another fitting I have for up higher is a 3/4 npt bung where I’ll attach the air compressor QD, then just add pressure to the tank with a hose connected to the boiler drain........ empty tank.
 

Attachments

  • 638E6610-8F8D-4D24-921C-3C0872EF3F25.jpeg
    638E6610-8F8D-4D24-921C-3C0872EF3F25.jpeg
    177.1 KB · Views: 352
  • FEFF1796-EDE8-4CFA-BFE0-FD0D4D869DCF.jpeg
    FEFF1796-EDE8-4CFA-BFE0-FD0D4D869DCF.jpeg
    177.2 KB · Views: 314
where I’ll attach the air compressor QD, then just add pressure to the tank

What do you mean there? Air compressor?

Check out my post #43, you can see the blue air line. I am talking about if I ever have to drain the tank I can start pumping air into it to force out the water.
 
Check out my post #43, you can see the blue air line. I am talking about if I ever have to drain the tank I can start pumping air into it to force out the water.
Gravity not good enough?
 
I have never heard of anyone doing that before on a boiler or tank or it even being a consideration.

Don't think that needs a separate or special fitting or anything if you did want to do it - you could just thread an air fitting into a pipe thread somewhere. But hooking an air compressor up to a heating system could make something go *sputz* that you don't want to.
 
Gravity not good enough?

the tanks are in the basement and i would prefer to dump the water directly outside rather than into buckets to bring up and outside. plus i wouldn't be able to drain the last foot or so out of them as the drain is about 3" off the ground so no way to get a bucket under it.

I have never heard of anyone doing that before on a boiler or tank or it even being a consideration.

Don't think that needs a separate or special fitting or anything if you did want to do it - you could just thread an air fitting into a pipe thread somewhere. But hooking an air compressor up to a heating system could make something go *sputz* that you don't want to.

yes that's what the ball valves are for, i am not planning on doing this once a week, just planning ahead for if i ever need to empty a tank. work smarter not harder
 
I didn't have to add any bungs to my tanks for temp wells.I used the same wells as used for aquastates that thread in.I used the same gauges as Warno used from eBay.
 
my tanks don't have any bungs in useful locations since i cut and welded them back together. i just figured i needed more bungs for sensors but i guess i don't, not complaining since less work and less welding for me
 
I've used air pressure to force water from my tanks before. But if you do that be sure everything but the tanks are valves off. My tank has a 30 psi pop off in it so I could only use a small amount of air. If you're driving water up and out of your basement I'd probably just fashion a bulkhead fitting into a 5 gallon bucket and put a pump in it. Then pump it out.

But on your temp sensors just go with surface mount. No need to poke more holes in your tanks. For $10ish a piece sensors from China you can't go wrong.
 
Finally had time off work and other things to get some major progress.

Tom suggested putting a nice big clean 4x8 sheet of plywood on the wall so I can layout all the plumbing neatly and organized. Did that 2 weeks ago, talked with Chris AF HS Tarm, mapped out some prints and ordered parts online.

I’m not 100% on how to tie the tanks in yet, just using some random pipes I have laying around to mock up ideas. Will finalize it tomorrow with my plumber and buy more at the local HD.

I may do a 180* on the boiler for better fit and piping install. Anyone think running the exhaust pipe over the boiler a little would be a bad thing? I am going to use double wall SS pipe that gives me 6” min space from combustibles, however I should be well over 13” anyway.
 

Attachments

  • 09BFD305-F49D-4265-A0C0-8139B893CC35.jpeg
    09BFD305-F49D-4265-A0C0-8139B893CC35.jpeg
    167.4 KB · Views: 372
  • CE29A088-A0E8-45F8-837C-4BE5AA0CF1A5.jpeg
    CE29A088-A0E8-45F8-837C-4BE5AA0CF1A5.jpeg
    198.9 KB · Views: 364
  • B7DC78F4-19FC-42C4-9978-40059F7E9EA7.jpeg
    B7DC78F4-19FC-42C4-9978-40059F7E9EA7.jpeg
    146.5 KB · Views: 306
All mapped out, just need to order more fittings then start plumbing.
 

Attachments

  • 48D3F0A2-7772-4B59-9D0B-C5430B27DCC2.jpeg
    48D3F0A2-7772-4B59-9D0B-C5430B27DCC2.jpeg
    131.4 KB · Views: 324
  • B81F3038-4409-470B-B88B-D823F210535E.jpeg
    B81F3038-4409-470B-B88B-D823F210535E.jpeg
    202.1 KB · Views: 306
Parts came in so I did a quick mock up on the floor before work while I waited for the paint to dry.

Plumber friend said I had to paint it platinum grey since that’s what the pros do. ‍


i added labels and color to the pic so does this make sense?
i will be adding valves as needed as well as the heat exchange for the garage zone and radiant floor heating manifolds
 

Attachments

  • A333C699-71E9-4EFB-9597-18540359DA52.jpeg
    A333C699-71E9-4EFB-9597-18540359DA52.jpeg
    216.4 KB · Views: 301
  • 0E6783BB-DFD4-400C-8F01-B8F37CA87C32.jpeg
    0E6783BB-DFD4-400C-8F01-B8F37CA87C32.jpeg
    178.8 KB · Views: 314
  • labled boiler mock up.jpg
    labled boiler mock up.jpg
    378.9 KB · Views: 375
Last edited:
I may do a 180* on the boiler for better fit and piping install. Anyone think running the exhaust pipe over the boiler a little would be a bad thing?

Keep in mind your heat exchanger will need to be cleaned, leave yourself enough room with stack pipe.
 
I may do a 180* on the boiler for better fit and piping install. Anyone think running the exhaust pipe over the boiler a little would be a bad thing?

Keep in mind your heat exchanger will need to be cleaned, leave yourself enough room with stack pipe.

what do you mean?

that isn't the actual 1-1 model of what i am doing, just mock up for layout only, once i get the other stuff on the wall i'lll see where it mounts up and the best place to put it.

i had the boiler flipped and it doesn't leave me much room, i've tried it in 3 positions and this is the best one for my limited space
 
i think i have settled on my final layout

as for the yellow dot, do i need to put a valve of some kind there to restrict flow so with the circ is on and zones are open the hot water flows thru the zones instead of in a loop in the manifold?
 

Attachments

  • basement FINAL.jpg
    basement FINAL.jpg
    218.8 KB · Views: 339
Tom, I think you are good without it, if circs on and all zones are open, you’ll have the same flow on the returns, basically nullifying any differential pressure. However a ball valve is always handy for purging
 
i am going to add in a magnetic filter unit, where is the best place in my system to put that?
.
My initial instinct is to put that on the exit from the storage tanks as i am sure that is where the most metal particulate is. or am i wrong?
 
Almost ready to get it going on the oil boiler to test it all out. Working on figuring out the wiring and controls tomorrow.

Radiant floor Pex will get run soon.
 

Attachments

  • 4002F59B-42D9-4A1C-A312-F4B8C052B71B.jpeg
    4002F59B-42D9-4A1C-A312-F4B8C052B71B.jpeg
    181.7 KB · Views: 327
I think you need to rotate your terminal box on your circ to the top. I can't remember for sure but check the owner's manual. I believe it says to have it on top.