WRENCH said:
I have a Englander pellet stove, model 25-pdv/55-shp22. manf. date 11/00, WITH ISSUES. Issue being after I set my heat range and blower speed the stove will increase the both on it's own.I turn them back down and they go back up. Sometimes it won't allow me to turn them down without repetitive pressings of the control buttons. LOOKING FOR ANY HELP OR INSIGHT. Thanks
Wrench, one thing you could try is to do a hard control board reset. It works on the newer stoves, so I'm hoping it's the same on the older ones too:
1. Shut off stove, and allow to cool off completely.
2. Unplug stove, and after a few seconds plug back in....within 3-4 seconds, press all 3 bottom buttons at the same time, and let go.
3. "F-5" should appear in the display. Allow the display to go blank.
4. Re-start stove.
If this doesn't work ( if you don't get the F-5 readout), I'd call Englander Tech support and have them go through some other diagnostics.