chimney liners....

  • Active since 1995, Hearth.com is THE place on the internet for free information and advice about wood stoves, pellet stoves and other energy saving equipment.

    We strive to provide opinions, articles, discussions and history related to Hearth Products and in a more general sense, energy issues.

    We promote the EFFICIENT, RESPONSIBLE, CLEAN and SAFE use of all fuels, whether renewable or fossil.
Status
Not open for further replies.

goofa

Burning Hunk
Oct 7, 2012
154
Central New York
Rigid or flex. 20' interior chimney with 8" square clay. thimble is accessible at the top of the clean out door.
 
It would be very hard to get a rigid liner down most likely. The clay tiles are usually not stacked right on top of each other making it almost impossible. It would be best to use flex with a nose cone.
 
At 20 ft you should be ok running a flex 6" liner down that chimney, if you are going to do it right I would have it inspected to see if you have cracks in your terracotta, if you have cracks it means you need to use an insulated liner, which would put you down to a 5.5" insulated liner, not sure that would work good on the ol Fisher.
 
We like flex, as its expansion/contraction sheds some of the creosote and runs a bit cleaner and, with poured insulation, they work really well even if you decide to down size, although I agree that reducing your old Fisher this much could be a problem.
 
  • Like
Reactions: webby3650
So a newer stove is capable of running on 5.5" flue? can i get away without the insulation being the chimney is located in the center of the house? probably only 8' of chimney that is exposed to the climate ... 4' in the attic and 4' above roof line.
 
Interior or Exterior chimneys need to have the liner insulated IF you have ANY cracks in your terracotta, that is code.

Newer stoves with a 6" exhaust are capable of running on taller 5.5" liners, it is better to insulate the smaller liner for even better draft even if you don't have cracks and have an interior chimney.
 
At 20 ft you should be ok running a flex 6" liner down that chimney, if you are going to do it right I would have it inspected to see if you have cracks in your terracotta, if you have cracks it means you need to use an insulated liner, which would put you down to a 5.5" insulated liner, not sure that would work good on the ol Fisher.

This is getting just a little off topic, but I didn't think the terracotta had anything to do with the liner? Don't some people bust out the clay liner when installing flex liner?
 